Installation Instructions
4FASTEN THE SHUTOFF VALVE
Fasten the
Pipe Clamp
| Vertical Cold Water Pipe | |
| ||
Off Valve |
|
|
NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber.
7CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for copper tubing onto the end of the tubing and connect it to the
Make sure the tubing is fully inserted into the valve. Tighten the compression nut securely.
For plastic tubing from a GE SmartConnect™ Refrigerator Tubing kit, insert the molded end of the tubing into the
Compression Nut | |
SmartConnect™ |
Tubing |
Tighten the clamp screws until the sealing washer begins to swell.
Packing Nut
Outlet Valve
Ferrule (sleeve)
NOTE: Do not overtighten or you may crush the tubing.
Washer
Pipe Clamp | Inlet End |
|
Clamp
Screw
6ROUTE THE TUBING
Route the tubing between the cold water line and the refrigerator.
Route the tubing through a hole drilled in the wall or floor (behind the refrigerator or adjacent base cabinet) as close to the wall as possible.
NOTE: Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use is not permitted in Massachusetts. Consult with your licensed plumber.
8FLUSH OUT THE TUBING
Turn the main water supply on and flush out the tubing until the water is clear.
Shut the water off at the water valve after about one quart (1 liter) of water has been flushed through the tubing.
To complete the installation of the refrigerator, go back to Step 1 in Installing the Refrigerator.
35