| Table 1. | Failure Causes |
| |
|
|
|
|
|
|
| Freezer Compartment |
| Fresh Food Compartment | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
| compartment thermistor | ||
|
|
|
| ||
|
| Condensor fan failure |
|
| Damper closed |
|
|
|
|
| |
|
| Evaporator fan failure |
|
| Evaporator fan failure |
|
|
|
|
| |
|
| Defrost heater stuck on |
|
| Door switch failure |
|
|
|
|
| |
Above 15 |
| Door switch failure |
| Above 50 | Main control board faulty |
|
| Harness faulty | |||
Fahrenheit |
| Main control board faulty |
| Fahrenheit | |
|
|
| |||
|
| Harness faulty |
|
| Door gasket leak |
|
|
|
|
| |
|
| Dispenser flap open |
|
| Door open |
|
|
|
|
| |
|
| Door gasket leak |
|
|
|
|
| Door open |
|
|
|
|
| Sealed system failure |
|
|
|
|
|
|
|
|
|
|
| Cycle Normal |
|
| Cycle Normal |
(between 14 and |
| (between 49 and 33 Fahrenheit) | |||
|
|
|
|
|
|
|
| Damper stuck closed |
|
| Damper stuck open |
|
| Low resistance in freezer thermistor |
|
| |
|
| Main control board faulty |
|
| compartment thermistor |
Below |
|
| Below 32 |
| |
| Harness faulty |
| Main control board faulty | ||
Fahrneheit |
|
| Fahrenheit | ||
|
| Ambient temperature below 60 | |||
|
|
|
|
| |
|
|
|
|
| Harness faulty |
|
|
|
|
|
|
– 33 –