GE GSS20, GSS22, GSS25, ESS25, ESS22, HSS25, HSS22, SSS25 manual Compressor Not Running

Models: SSS25 HSS22 HSS25 ESS22 ESS25 GSS25 GSS20 GSS22

1 70
Download 70 pages 3.51 Kb
Page 49
Image 49
Compressor Not Running

Compressor Not Running

Unplug refrigerator

Warm freezer thermistor to 70 F Connect power and set temperature controls to 5 and 5.

Is the compressor running?

Yes

Adjust settings and allow

24 hours to stabilize

 

 

No

 

 

Check for 120VAC at connector J7-9 orange wire to TERMINAL-J8 black wire. Do you have 120VAC?

No

Replace main board

Yes

Direct test the compressor. Did it start?

Yes

Check wiring to

compressor,

overload & relay

No Replace Manual backgroundManual background compressor

– 47 –

Page 49
Image 49
GE GSS20, GSS22, GSS25, ESS25, ESS22, HSS25, HSS22, SSS25 manual Compressor Not Running