Compressor Not Running
Unplug refrigerator
Warm freezer thermistor to 70 F Connect power and set temperature controls to 5 and 5.
Is the compressor running? | Yes | Adjust settings and allow | |
24 hours to stabilize | |||
|
| ||
No |
|
|
Check for 120VAC at connector
No
Replace main board
Yes
Direct test the compressor. Did it start?
Yes
Check wiring to
compressor,
overload & relay
No Replace compressor