Condenser Fan Not Running
Always check fan for obstruction first.
Unplug refrigerator to reset
main control board.
Warm freezer thermistor to 70 F
and set temperature controls to 5 and 5. Reconnect power.
At the condenser fan connector, check |
|
|
|
|
|
|
| |||
for 13VDC from the red to white wire and |
|
|
|
| Replace condenser | |||||
|
| Yes |
| |||||||
|
|
|
| fan motor | ||||||
|
|
|
|
| ||||||
|
|
|
|
| ||||||
Is the voltage correct for both? |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Unplug J2 connector on the main control board. |
|
|
| Repair wiring | ||||||
Check for 13VDC between pins |
|
|
| |||||||
| Yes |
| between main control board | |||||||
and |
|
| ||||||||
|
|
| and condenser fan motor | |||||||
|
|
| ||||||||
Is the voltage correct for both? |
|
|
|
|
|
| ||||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| No |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| NOTE: When no voltage at main | ||||
|
|
|
|
|
| |||||
Replace main control board |
|
| ||||||||
|
| control board, make certain to | ||||||||
|
|
|
|
|
| |||||
|
|
|
|
|
| check for shorted fan motor (less | ||||
|
|
|
|
| than 1K ohm between white to red | |||||
|
|
|
|
|
| or white to yellow). A shorted fan | ||||
|
|
|
| motor will damage the replacement | ||||||
|
|
|
|
|
|
|
| main board. |