Refrigerator Dead, No Sound, No Cooling
Are the interior lights on?
|
|
| Check house supply voltage. |
|
|
| House wiring | |
No |
|
|
| No |
| |||
|
| Do you have 120VAC? |
|
| problem | |||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Yes
Yes
Check for 120VAC at 6 pin connector at rear of unit. Do you have 120VAC?
Yes
Repair wiring connections at 6 pin connector
No | Repair or replace | |
power cord | ||
|
If dispenser model,
does dispenser
operate?
(If
follow No statement
path first)
Yes
|
|
| Unplug J2 connector from |
| |||
|
|
| main control board. |
| |||
No |
|
| Check for 12 VDC at control |
| |||
|
| ||||||
|
|
| board pins |
| |||
|
|
| |||||
|
|
| Do you have voltage? |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yes |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Short in fan motor circuit |
| |||
|
|
| Go to fan flowcharts |
|
|
|
| Unplug J4 connector from | |||
|
|
| main control board. | |||
No |
|
| Check for 12 VDC at control | |||
| ||||||
|
|
| board pins | |||
|
|
| ||||
|
|
| Do you have voltage? | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Yes |
| |
|
|
|
|
|
|
|
|
|
| Short in dispenser control | |||
|
|
| circuit. Repair short or replace | |||
|
|
| dispenser board. |
No | Replace main | |
control board | ||
|
NOTE: check all fan
motors circuit for shorts. If short is detected, repair short or replace fan motor. Failure to replace shorted component will damage the new control board upon installation
Unplug encoder
(temperature control) harness. Does the refrigerator start once the harness is unplugged?
Yes
Replace encoder board (temperature control)
No
Verify thermistors are within proper range using temperature resistance chart on page 49.
Is the resistance within range?
Yes
Replace main control board
Check wiring connections
No If wiring is OK, replace thermistor
– 43 –