Damper Door Not Operating
Push on damper door to check
manual movement.
Is the damper door stuck?
No
Push damper halfway closed. Unplug refrigerator to reset main control board.
Set temperature controls to 5 and 5
Reconnect power.
Does damper door move
after immediately
reconnecting power?
(you have 10 seconds to check)
Damper jammed
Yes Remove blockage or replace damper
|
|
| Verify thermistors are within proper |
| |||
|
|
| range using temperature resistance |
| |||
Yes |
|
| |||||
|
| chart on page 49 |
| ||||
|
|
|
| ||||
|
|
| Is the resistance within range? |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
Yes | Replace main | |
control board | ||
|
No
Unplug harness connector at damper.
Measure resistance between the
yellow
and red/black wires and between the white/brown and blue/yellow wires.
Do you measure approximately 420 ohms for both readings?
No
Replace damper
Check wiring connections
If wiring is OK,
replace thermistor
|
|
| Unplug J3 connector from main control |
| |||
|
|
| board. Unplug refrigerator to |
| |||
|
|
| reset, then reconnect power. |
| |||
Yes |
|
| Do you have 6VDC between pins |
| |||
|
| ||||||
|
|
|
| ||||
|
|
|
| ||||
|
|
| pins |
| |||
|
|
| (you have 10 seconds to check) |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
| |
|
|
|
|
|
|
|
|
|
|
| Replace main |
| |||
|
|
| control board |
|
Look for wiring problem
between main control board
Yes and damper. If wiring is OK, replace damper.
– 46 –