Installation Preparation
NOTE: A
WARNING
The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected
to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw.
•Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.
•Remove the ground strap. DO NOT DISCARD THE GROUND STRAP OR ANY SCREWS.
•Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate and into the frame of the range.
•Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position
of the terminal block. Tighten screws securely into the terminal block.
Before | Ground Strap | |
| ||
Terminal | or | |
| ||
Block |
| |
Ground Strap | Neutral | |
Terminal | ||
| ||
After |
| |
| Neutral Terminal | |
Terminal | Ground Plate | |
Block | ||
(grounding to | ||
| ||
| range) | |
Ground |
| |
Screw |
|
NOTE: A
WARNING
The neutral or ground wire of the power cord must be connected to the neutral terminallocated in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block.
•Remove the ground strap (located at the right side of the terminal block) and connect between the center lower portion of the terminal block to the frame of the range.
•Remove the 3 lower terminal screws from the terminal block. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position
of the terminal block. Tighten screws securely into the terminal block.
DO NOT remove the ground strap connection.
Terminal Block (appearance may vary)
Neutral
Terminal
Ground
Plate
Ground
Strap
Power Cord