Installation
WARNING
Do not use a flame to check for gas leaks.
Assure that gas supply is turned off at the•Apply pipe thread sealant to the gas inlet located at the back of the range. Install the 1/2" pipe elbow (provided) to the gas inlet.
•Connect 5/8" O.D. flexible metal connector
to gas inlet. Connect the other end of the flexible connector to the house gas supply.
•Turn on the gas and check for leaks:
–Use a liquid leak detector at all joints and connections in the system.
Gas
Inlet
IMPORTANT: Disconnect the range and the individual
1/2 psig.
NOTE: This range is equipped with a gas
WARNING
The
•Check to be sure the appliance runners are beneath the wheels.
•The range is shipped with the wheels in the down position. Carefully roll the range into position, being careful not to entangle or pinch the power cord and flexible gas tubing.
•Remove the runners beneath the range.
Be sure
on the range.
•Plug power cord into properly grounded receptacle.
•Verify that power is connected by opening
the oven door or press the button on the left side of the control panel to illuminate the accent lighting.
14