Installation Instructions

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANTSave these instructions for local inspector’s use.

IMPORTANTObserve all governing codes and ordinances.

Noteto Installer Be sure to leave these instructions with the Consumer.

Noteto ConsumerKeep these instructions with your Owner’s Manual for future reference.

Completion Time 1 to 3 hours.

Proper installation is the responsibilityof the installer. Product failuredue to improper installationis not covered under the warranty.See Owner’s Manual for warranty information.

WARNING:

This appliance must be properly grounded. See ”Electric Supply.”

For Monogram localservice in your area, 1.800.444.1845.

For Monogram Service in Canada, call 1.800.561.3344.

For Monogram Parts and Accessories, call 1.800.626.2002.

If you received a damaged range, you should contact your dealer.

In the Commonwealth of Massachusetts:

This product must be installedby a licensed plumberor gas fitter.

When using balltype gas shut off valves,they shall be T-handle type.

A flexiblegas connector,when used, mustnot exceed 3 feet.

WARNING:

All ranges can tip. Injury could result. Install the supplied Anti-Tip Bracket provided. See instructions in this manual or with the bracket.

If sold outside the U.S. and Canada:

WARNING:If you wish to use this product with LiquefiedPetroleum (LP) gas containing greaterthan10% butane, you must purchase the butaneconversionkit #WB28K10589.To order, pleasecall 1.888.664.8403

or 1.787.276.4051.

2

Vent hood Combinations:

It is recommended that these ranges be installed in conjunction with a suitable overhead venthood.

Install a hood with at least 1200 CFM above a 48" wide range.

Install a hood with at least 600 CFM above a 30" or 36" range.

Due to the highheat capacity of this unit, particularattention should be paid to the hood and ductwork installation to assure it meets local building codes.

WARNING:

Clearances to horizontal surfaces above the range, measured to the cooking surface:

Installations without a hood require 48" minimum to combustibles.

A custom hood installation with exposedhorizontal combustibles surfaces must have an Auto-On feature.

For other installationswith a hood, refer to hood installation instructionsfor specific hood clearances.

CAUTION:

These ranges weigh up to 700 pounds. Some disassembly will reduce the weight considerably. Due to the weight and size of the range and to reduce the risk of personal injury or damage to the product:

TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION OF 36" AND 30" RANGES.

THREE PEOPLE ARE REQUIREDFOR PROPER INSTALLATION OF 48" RANGES.

Leak testing of the appliance shall be conductedaccording to the manufacturer’s instructions.

Installation must conform with local codes. In the absence of local codes, the range must complywiththe National Fuel Gas Code, ANSIZ223.1/NFPA 54, latest edition and National Electrical Code ANSI/NFPA 70 latest addition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1or the current Propane Installation Code, CAN/CGA-B149.2, and withlocal codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latestedition and Canadian Gas Association according to CAN/CGA-1.1 latest edition.