GE ZV800 Wall Mount Installations, Installation Below A Cabinet, Installation Preparation

Models: ZV800

1 24
Download 24 pages 18.87 Kb
Page 7
Image 7
WALL MOUNT INSTALLATIONS

Installation Preparation

WALL MOUNT INSTALLATIONS

These hoods may be installed onto a wall or below a wall cabinet.

Telescopic duct covers are provided to conceal the ductwork, running to the ceiling.

This hood can be installed for recirculating operation. No kits required.

24” Min.

30” Max.

36” Min.

The vent hood must be installed 24” min. and 30” max. above the cooking surface. The hood installation height, from the cooking surface to the bottom

of the hood, depends upon ceiling height.

INSTALLATION BELOW A CABINET

*20” Min.

24” Min.

*The cabinet must measure at least 20” from the bottom frame to the inside top. The hood housing will occupy the interior cabinet space.

Wall Mount ZV800 Installation Heights

Actual

 

*Possible

Celing

*Possible VENTED

RECIRCULATING

Height

Installation Height

Installation Height

 

 

 

7’11”

24” to 27”

24” to 25”

 

 

 

8’ 0”

24” to 28”

24” to 26”

 

 

 

8’ 1”

24” to 30”

24” to 27”

 

 

 

8’ 2”

24” to 30”

24” to 28”

 

 

 

8’ 3”

24” to 30”

24” to 29”

 

 

 

8’ 4”

24” to 30”

24” to 30”

 

 

 

8’ 5”

24” to 30”

24” to 30”

 

 

 

8’ 6”

24” to 30”

24” to 30”

 

 

 

8’ 7”

24” to 30”

24” to 30”

 

 

 

8’ 8”

24” to 30”

24” to 30”

 

 

 

8’ 9”

24” to 30”

24” to 30”

 

 

 

8’ 10”

24” to 30”

24” to 30”

 

 

 

8’ 11”

24” to 30”

24” to 30”

 

 

 

9’ 0”

24” to 30”

24” to 30”

 

 

 

9’ 1”

24” to 30”

24” to 30”

 

 

 

9’ 2”

24” to 30”

24” to 30”

 

 

 

9’ 3”

24” to 30”

24” to 30”

 

 

 

9’ 4”

24” to 30”

24” to 30”

 

 

 

9’ 5”

24” to 30”

24” to 30”

 

 

 

9’ 6”

24” to 30”

24” to 30”

 

 

 

9’ 7”

25” to 30”

24” to 30”

 

 

 

9’ 8”

26” to 30”

24” to 30”

 

 

 

9’ 9”

27” to 30”

24” to 30”

 

 

 

9’ 10”

28” to 30”

24” to 30”

 

 

 

9’ 11”

29” to 30”

25” to 30”

 

 

 

10’

30”

26” to 30”

 

 

 

*Based on 36” countertop height.

INSTALLATION BELOW

A WALL CABINET

Order a cabinet that is at least 20” high from the bottom frame to the inside top. The cabinet must be at least 12” deep.

The hood installation height is determined by the ceiling height.

The hood installation height must be 24” Min. above the cooking surface.

7

Page 7
Image 7
GE ZV800 Wall Mount Installations, Installation Below A Cabinet, Installation Below A Wall Cabinet