Installation Instructions

WALL-MOUNTED INSTALLATION—RECIRCULATING

4 MOUNT THE HOOD

Install a wood screw

Mounting

on each side of the

bracket

mounting frame

 

Lift the hood onto the mounting bracket.

Check to be sure it is level.

Install wood screws through the hood and into the wall on each side of the mounting bracket.

Install bottom

mounting

screws

Extend the canopy forward for better access to the rear mounting screw holes.

Install 2 wood screws or fasteners through the bottom of the hood into the wall.

5SIZE AND CUT DUCT PIECE

Hold upper air deflector with duct connector against the

ceiling.

Measure from the bottom of

the air deflector to the top of

 

the hood as shown. Reduce

 

that dimension by 1” to

 

facilitate installation.

 

 

The duct will cover

 

Duct length

and overlap the

Measure

deflector and the

 

length

 

hood outlets.

 

 

 

5SIZE AND CUT DUCT PIECE (cont.)

Cut the duct piece to size and slip onto the bottom of the duct

connector.

Use duct tape to seal and secure

the duct piece to the connector.

Place the assembly over the hood outlet.

Hold the assembly against the ceiling. The penciled centerline should show through the slot in the deflector. Mark the screw holes on the sides of the assembly.

Remove the assembly and drill 1/8” pilot holes into the wall studs.

Enlarge holes that did not enter studs to 3/8” and tap plastic or metal anchors into the holes, flush with the wall.

Mount the assembly onto the hood outlet, push up against the ceiling and install the screws provided.

CAUTION: Do not use sheet metal screws at the hood flange connection. Doing so will prevent proper damper operations. Seal connection with tape only.

ATTENTION : N’utilisez pas de vis autotaraudeuses pour connecter le rabat de la hotte. En utilisant des vis, vous empêchez le bon fonctionnement du volet de fermeture. Scellez la connection uniquement avec du ruban adhésif.

16

Page 16
Image 16
GE ZV800 installation instructions Size and CUT Duct Piece, Overlap, Deflector, Hood outlets