DC1/DC3 Control
Y: The printer will respond to a received DC1/DC3, which causes the printer to be selected/deselected. If the printer is deselected, the LCD will show STAND BY until DC1 is received or until you put the printer ON LINE by depressing the ON LINE key once.
N: Received DC1/DC3 ignored.
PAR: RCV DC1/DC3 | ENTER |
PAR:DC1/DC3>Y | ↓ |
PAR:DC1/DC3:N | ↓ |
Init Signal |
|
Y: Enables parallel interface INIT signal to reset printer.
N: Disables parallel interface INIT signal.
PAR: INIT ENABLE | ENTER |
PAR:INIT ENBL>N | ↓ |
PAR:INIT ENBL:Y | ↓ |
Fault Lead |
|
NONE: Printer does not indicate activity on Fault lead
ONLN: Printer indicates ON LINE status on Fault lead.
FAUL: Printer indicates fault status on Fault lead.
PAR: FAULT LEAD | ENTER |
PAR:FAULT>NONE | ↓ |
PAR:FAULT:ONLN | ↓ |
PAR:FAULT:FAUL | ↓ |
63