CONNECTING ACCESSORIES

CONNECTING ACCESSORIES

Make sure the control box power switch is OFF before connecting accessories.

The ACCESSORY terminal block is the connection point for accessories such as push buttons, safety loops, intercoms, etc. The ACCESSORY terminal marked GRN (green) is the common ground for all accessories. GRN is paired with the terminals shown below when connecting accessories to the control board.

IMPORTANT: Make sure to twist exposed wires tightly and insert them into the terminals without loose strands. Tighten set screws against exposed end of wires. A dab of household petroleum jelly in each terminal will help prevent corrosion.

WHT (WHITE) USED WITH GRN (GREEN):

This is the most frequently used pairing for a doorbell button, keypad, or keyswitch. Accepts input from or is used with N/O contact devices.

SEQ1

ON

 

 

SEQ2

 

LEARN

 

 

 

 

GRN ORG

BLU

WHT

R

B

G

ALARM

ACCESSORY

 

RCVR

 

First contact will start the gate.

Second contact will stop the gate.

Third contact will reverse the gate.

NOTE: Never use a lighted doorbell button!

It will discharge the battery and the gate operator will fail to operate.

Low Voltage Wire from Doorbell Button, Keypad, or Key Switch

BLU (BLUE) USED WITH GRN (GREEN):

This pairing is typically used for a free exit or free entry devices. Accepts input from or is used with N/O contact devices

First contact will open the gate.

NOTE: If the gate is in the open position and begins to close, the activation of the accessory device will reopen the gate. In communities where the use of an emergency entry device is mandatory, it should be connected to these terminals.

SEQ1

ON

 

 

SEQ2

 

LEARN

 

 

 

 

GRN ORG

BLU

WHT

R

B

G

ALARM

ACCESSORY

 

RCVR

 

Low Voltage Wire from Free Entry or Free Exit Devices

ORG (ORANGE) USED WITH GRN (GREEN):

This pairing is frequently used for safety loops. Accepts input from or is used with N/O contact devices.

This connection will not open your gate. The safety loop will activateonlywhilethegateisinuse. Whenusingthiscombination, the gate will remain open or reopen if it is closing.

SEQ1

ON

 

 

SEQ2

 

LEARN

 

 

 

 

GRN ORG

BLU

WHT

R

B

G

ALARM

ACCESSORY

 

RCVR

 

Low Voltage Wire from Safety Loops

26