SINGLE GATE OPERATOR INSTALLATION

GATE PREPARATION

Be sure the gate is properly installed and slides smoothly before installing the GTO/PRO Slide Gate Operator. The gate must be plumb, level, and move freely. The gate must not bind or drag on the ground. Never use a wheel on the gate, because the additional drag and resistance can cause the operator to obstruct.

Level

Plumb

Concrete

Concrete

OVERVIEW OF OPERATOR INSTALLATION

The diagram below shows a single slide gate installation with recommended safety features. The operator must be installed on the inside of the gate. GTO requires using safety edges and roller guards to help reduce the possibility of bodily injury.

 

 

 

Contact Sensor

 

 

Roller Guard

(REQUIRED)

 

 

 

Contact Sensor

Contact Sensor

(REQUIRED)

Receiver

 

(REQUIRED)

(REQUIRED)

 

(cable in separate

 

 

 

conduit)

!WARNING

Moving Gate Can Cause

120 Volt Indoor

Injury Or Death

Transformer

Chain Bracket

Chain Bracket

 

STAND CLEAR

(Surge Protector

 

 

 

CAUTION

not supplied)

 

Operator

 

Chain

Roller Guard

 

(REQUIRED)

Roller Guard

 

(REQUIRED)

 

Use PVC Conduit

Run 1000' (max.) of low

voltage wire to control

(not included)

box from transformer

for power cables.

(wire not included).

12

Page 14
Image 14
GTO SL-1000B, SL-2000B Single Gate Operator Installation, Gate Preparation, Overview of Operator Installation