GTO SL-2000B, SL-1000B see Illustration K, 18VAC, illustration L. Transformer, Step

Models: SL-1000B SL-2000B

1 43
Download 43 pages 59.51 Kb
Page 21
Image 21
(see Illustration K).

INSTALLATION OF THE GTO TRANSFORMER CONT.

STEP 12:

Illustration K

 

 

 

 

Strip 3/16” off the ends of the low voltage wire and

Correct

 

Wrong

Wrong

 

twist tightly. These wire ends will be attached to

 

 

 

 

 

 

 

 

the control board at the 18VAC terminals located

 

 

 

 

 

 

on the POWER IN terminal block (see Illustration

 

 

 

 

 

 

L).Wire sheathing should not come in contact with

 

 

 

 

 

 

terminals, however, it should not be stripped so far

 

 

 

 

 

 

that wires can come in contact with one another

 

 

 

 

 

 

(see Illustration K).

Wire

Terminal

Wire

Terminal

Wire

Terminal

 

Block

Block

Block

Insert one transformer wire

 

 

 

 

into an

18VAC terminal.

 

 

 

 

Insert the other transformer

 

 

 

 

wire into the remaining

 

 

 

 

18VAC

terminal

( see

 

RED BLK ORG BLU GRN CLSEDG

OPNEDG

RE

illustration L). Transformer

18VAC SOLAR

wires can be connected to the

~ ~ – +

 

 

 

 

 

 

 

18VAC terminals regardless

 

 

 

 

of color.

 

 

POWER IN

FIRST OPERATOR

 

SECOND OPER

Tighten set

screws

against

 

exposed end of wires (see

 

Illustration

K). A

dab of

RED BLACK

household petroleum jelly

 

on each wire end will help

 

prevent corrosion.

 

 

The ACCESSORY terminal

Power Cable

block provides the connection

point for safety loops, wands,

from First Operator

 

push buttons, intercoms, card

 

readers, etc.

See

page 27

Low Voltage Wire

for more information about

connecting accessories.

from AC Transformer

 

Transformer

18VACSURGE PROTECTOR

HINT: Keep a few mothballs in the control box to discourage insects from entering it and damaging the control board.

STEP 13:

Plug the transformer into the electrical outlet. Check to see if the green LED on the control board is on. If it is not, see the Troubleshooting Guide on page 30.

NOTE: Use of a surge protector is strongly recommended.

19

Page 21
Image 21
GTO SL-2000B see Illustration K, 18VAC, illustration L. Transformer, NOTE Use of a surge protector is strongly recommended