SETTING THE PERSONAL TRANSMITTER CODE
All GTO transmitters are set to a standard code at the factory and are ready to activate the automatic gate operator. For safety and security, however, we strongly recommend that the factory setting be replaced with a personal code. Follow the directions below:
1.REMOVE THE TRANSMITTER COVER
On the back of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter. With the front cover removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches.
2.SET THE TRANSMITTER DIP SWITCHES
LED
+ | 1 | 2 |
|
0 |
|
| |
– |
| 3 |
|
|
| 4 |
|
|
| 5 | 6 |
A23S |
| ||
| 7 | ||
|
|
| 8 |
ALKALINE |
|
| 9 |
| 12V | ECE | |
| BA |
| |
|
| TTER |
|
|
| Y |
|
There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0,
WARNING: No other adjustments should be made inside the transmitter.
+1 2 3 4 5 6 7 8 9 0
ECE
3.“TEACH” THE NEW CODE TO CONTROL BOARD MEMORY
A.Turn control box power switch OFF.
B.Unscrew and remove the control box cover.
C.Press and hold the LEARN button on the control board, and turn the power switch ON. Release LEARN button. Wait 15 seconds for the receiver to charge.
D.Press and hold transmitter button until the red STATUS LED comes ON.
E.Release transmitter button. The new code is stored in the control board memory.
STATUS
STATUS LED
PULL/PUSH |
|
| 4 |
|
| ||
SNGL/DUAL |
|
| 3 |
SEQ1 | ON |
| 2 |
SEQ2 |
| 1 | |
|
|
|
|
AUTOCLOSE
60
OFF120
INERTIA
MINMAX
OBSTRUCT
SENS.
MINMAX
LEARN
R | B | G |
| RCVR |
Replace the control box cover and turn the power switch to the ON position.
22