Haier 1590 SB, 3150 SB, 3150 SF Troubleshooting, Problem, Follow Pressure Relief Proce, 310622L

Models: 1590 SB 3150 SA 3150 SF 1590 SA 3150 SB

1 40
Download 40 pages 55.19 Kb
Page 14
Image 14
Troubleshooting

Troubleshooting

Troubleshooting

Relieve the pressure before checking or servicing the equipment.

Check all possible problems and causes before disassembling the pump.

PROBLEM

CAUSE

SOLUTION

 

 

 

Pump cycles at stall or fails to hold

Worn check valve balls (541) or

Replace. See page 19.

pressure at stall.

seats (233).

 

 

 

 

Pump will not cycle, or cycles once

Air valve is stuck or dirty.

Disassemble and clean air valve.

and stops.

 

See page 16. Use filtered air.

 

 

 

 

Check valve ball (541) severely

Replace ball and seat. See page

 

worn and wedged in seat (233) or

19.

 

manifold.

 

 

 

 

 

Check valve ball (541) is wedged

Follow Pressure Relief Proce-

 

into seat (233), due to overpressur-

dure, page 10. Disassemble ball

 

ization.

check assembly and inspect for

 

 

damage, see page 19.

 

 

 

 

Dispensing valve clogged.

Relieve pressure and clear valve.

 

 

 

 

Leak detector has activated a shut-

Investigate failure and reset leak

 

down solenoid

detector

 

 

 

Pump operates erratically.

Clogged suction line.

Inspect; clear.

 

 

 

 

Sticky or leaking balls (541).

Clean or replace. See page 19.

 

 

 

 

Diaphragm ruptured.

Replace. See page 21.

 

 

 

 

Restricted exhaust.

Remove restriction.

 

 

 

Air bubbles in fluid.

Suction line is loose.

Tighten.

 

 

 

 

Diaphragm ruptured.

Replace. See page 21.

 

 

 

 

Loose inlet manifold, damaged seal

Tighten manifold clamps or replace

 

between manifold and seat, dam-

seats or gaskets. See page 19.

 

aged gaskets.

 

 

 

 

14

310622L

Page 14
Image 14
Haier 1590 SB, 3150 SB, 3150 SF, 3150 SA, 1590 SA Troubleshooting, Problem, Follow Pressure Relief Proce, 310622L