Check Valve Repair
Disassembly
Reference numbers with an asterisk (*) are replacement parts. For a complete list of replace- ment parts see Parts, page 26.
1.Relieve the pressure. Disconnect all hoses.
2.Remove the pump from its mounting. Drain.
3.From the outlet manifold, remove both upper clamps (132a).
4.Remove outlet manifold leaving elbows (128), gas- kets (129), clamps (130), and tee (339) assembled.
5.For 3A Ball Check pumps: remove ball gasket (240). Remove middle clamp (132c) and ball stop housing (2XA). Remove middle gasket (240) and ball (541). Remove lower clamp (132b), seat (2XB), and gasket (240). Clean all parts and inspect for wear or dam- age. Replace parts as needed.
128 |
|
132a |
|
*240 |
|
2XA | 129* |
132c | 130 |
| |
*240 |
|
*541 |
|
2XB |
|
*240 |
|
132b |
|
Service
3A Ball Check Assembly
FIG. 13
TI8768a
310622L | 19 |