Hasselblad H2 Separate flash unit connection and use, Flash measure of separate flash unit

Models: H2

1 91
Download 91 pages 37.68 Kb
Page 77
Image 77

1

2

FLASH

34

�����

 

����

56

AE-L

Separate flash unit connection and use

Separate flash units can be electrically connected either by way of the hot shoe accessory holder (see previous warnings) on the top of the viewfinder or via a cord to the PC connection port on the left hand side of the camera body. Slave unit switches/ transmitters can also be connected similarly dependant on unit (see specific user manuals for details).

Keep the plastic safety cover in place in the hot shoe when not in use.

Flash measure of separate flash unit

You can measure the effect of an attached flash unit (with PC connected flash units and SCA3902 compatible flash units set to M mode), where the camera acts much as a flash meter would. By choosing ‘Flash measure’, a trial exposure is made with the aux- iliary shutter still in place which therefore prevents film frames from being used. The aperture setting can be adjusted and more trial exposures made until the information on the grip LCD is satisfactory.

To use flash measure:

1)Press the FLASH button on the grip to access the flash option screen.

2)Turn the rear control wheel until Flash measure appears.

3)Press Save (DRIVE button) to access the flash exposure screen.

4)Make preliminary required aperture setting by turning the front control wheel.

5)Press the AE-Lbutton. The camera will close the aperture, raise the mirror and fire the flash. Light reflected from the flash lit subject will be reflected off a white spot on the auxiliary shutter to the meter sensor.

6)Deviations from a normal exposure are displayed as differ- ences in EV on the grip LCD and the viewfinder LCD. If ‘high’ or ‘low’ appears, change the aperture accordingly and make a new test reading.

Change the aperture until Diff EV: 0 appears, or the desired amount of deviation from the normal exposure.

Diff EV: Low signifies more than 2 EV under

Diff EV: High signifies more than 2 EV over

77