2. Top Vent - Vertical Termination

No Elbow

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

Note: Must have a 24 inches minimum vertical vent before attaching any elbow to the appliance.

V1

Figure 7.6

V1 = 50 ft. Max. (15.2 m) V1 = 3 ft. Min. (914 mm)

FLUE RESTRICTOR

NOTE: Flue Restrictor ships in manual bag assembly.

Note: Flue restrictor is permit- ted ONLY on 30 ft. minimum vertical runs with no elbows.

Note: Must have a 24 inches minimum vertical vent before attaching any elbow to the appliance.

 

V1

 

H1

V2

2 ft

 

610 mm

1 ft

305 mm

*

3 ft

 

914 mm

3 ft

914 mm

*

4 ft

 

1.2 m

4 ft

1.2 m

*

 

 

 

 

 

 

5 ft

 

1.5 m

9 ft

2.7 m

*

 

 

 

 

 

 

6 ft

 

1.8 m

12 ft

3.7 m

*

V1 + V2 + H1 = 50 ft (15.2 m) Max.

*No specific restrictions on this value EXCEPT V1 + V2 + H1 cannot exceed 60 ft (18.3 m).

After V1 = 6 ft, then H1 Max.= V1 x 2

Figure 7.7

Heat & Glo • ESC-42ST2146-900 Rev. o • 5/12

29

Page 29
Image 29
Heat & Glo LifeStyle ESC-42ST owner manual ft V1 + V2 + H1 = 50 ft 15.2 m Max