Heat & Glo LifeStyle ESC-42ST owner manual Facing Material, Doors

Models: ESC-42ST

1 68
Download 68 pages 2.4 Kb
Page 45
Image 45

23 IN.

 

3-1/2 IN.

 

NO COMBUSTIBLES

1/2 IN. BUILDING MATERIAL

IN THIS AREA

(MAY BE COMBUSTIBLE)

 

39 IN.

COMBUSTIBLE

 

 

FRAMING

4 IN.

 

 

FACTORY-

 

SUPPLIED 1/2 IN.

 

NON-

 

COMBUSTIBLE

 

BOARD

Figure 13.5

B. Facing Material

Metal front faces may be covered with non-combustible materials only.

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

COMBUSTIBLE MATERIAL

61-5/8 in.

0 in.

0 in.

0 in.

47-1/8 in.

NON-COMBUSTIBLE

BOARD

C. Doors

Only doors certified for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. Once you have determined what kind of door and finishing material is going to be used on the fireplace, you may use the table below which shows the door mod- els and the finishing material thickness allowed.

FS-E42-XX

FSA-ESC42ST-XX

(REQUIRES ARCHKIT-ESC-42ST)

Figure 13.7 Approved Doors for ESC-42ST

Note: Optional firescreen sits out 1-1/2 inches from the face of the fireplace. When using thin finishing material, you may want to use thicker non-combustible backer board to bring the finishing material flush with the firescreen. This is not required.

Figure 13.6 Noncombustible Facing Diagram

Heat & Glo • ESC-42ST2146-900 Rev. o • 5/12

45

Page 45
Image 45
Heat & Glo LifeStyle ESC-42ST owner manual Facing Material, Doors