Windows Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

22

Server With

If you configured CHAP security for the storage system, you must configure it for

Storage-system setup

 

CX500i Storage

the server’s iSCSI initiators.

guide and Manager

 

System

For NIC Initiators

online help

 

Configure

 

 

Use Navisphere Manager to enable CHAP on the storage system.

 

 

optional CHAP

 

 

 

 

 

security

Use Microsoft iSCSI Software Initiator to configure initiator CHAP on the

Storage-system setup

 

 

 

 

NIC initiators.

guide and Microsoft

 

 

 

documentation

 

 

For iSCSI HBA Initiators

Storage-system setup

 

 

Use QLogic SANsurfer to configure initiator CHAP on the HBA initiators.

guide and SANsurfer

 

 

documentation

 

 

 

 

 

Use Navisphere Manager to enable CHAP on the storage system

Storage-system setup

 

 

 

guide and Manager

 

 

 

online help

 

 

 

 

23

Server

Prepare the LUNs to receive data by creating partitions on them.

Host connectivity guide

 

Make LUNs

 

or Windows

 

 

documentation

 

available to

 

 

 

 

 

Windows

 

 

 

 

 

 

24

Windows Server

If you want applications to access SnapView functionality on the storage

CX-Series Server

 

2003 Server

system using the VSS framework or other APIs, Install the optional

Software for Windows

 

Install optional

CLARiiON VSS provider on the server.

Installation Guide

 

 

 

 

CLARiiON VSS

Note that Navisphere CLI must be installed on the server.

 

 

provider

 

 

 

 

 

 

25

Server

If you have a PowerPath license key

PowerPath product

 

Test PowerPath

Note If your PowerPath license key is not registered, the load balancing policy is

guide

 

with a license key

restricted to basic failover.

 

 

 

View the LUNs available to the server using the following PowerPath

 

 

 

command:

 

 

 

powermt display dev=all class=clariion

 

 

 

Choose one available LUN to receive I/O for the test.

 

 

 

View the paths to the chosen LUN using the following PowerPath

PowerPath product

 

 

command:

guide

 

 

powermt display dev=x every=2

 

 

 

where x is a pseudo device that represents the chosen LUN.

 

 

 

Start I/O to the LUN.

 

 

 

 

 

7-12

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 270
Image 270
EMC 69001166 Server With, System For NIC Initiators, For iSCSI HBA Initiators, Available to Windows, Install optional