Windows Installation Checklists

Task

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

13 CX-Series or

Use Navisphere Manager’s

Use the following Navisphere CLI

Navisphere Manager

FC4700-Series

Failover Setup Wizard (selected

command to determine the

administrator’s guide

Storage System

from the Tools menu on the

default storage-system type:

and online help or

Set properties for

toolbar) to set the following

navicli -h hostname systemtype

Navisphere CLI

storage-system properties for the

reference

PowerPath

server’s HBA or NIC ports

where hostname is the IP

 

 

 

 

(initiators):

address or network name of an

 

 

Initiator Type to CLARiiON Open

SP in the storage system.

 

 

If the default storage-system

 

 

Failover mode to 1

 

 

system type is not 3 (CLARiiON

 

 

Array commpath to Enabled

 

 

Open), use the following

 

 

Go to step 15.

Navisphere CLI command to set

 

 

it to 3:

 

 

 

 

 

 

navicli -h hostname systemtype

 

 

 

-config 3

 

 

 

CAUTION The above command

 

 

 

reboots both SPs at the same

 

 

 

time.

 

 

 

Use the following Navisphere CLI

Navisphere CLI

 

 

commands to set the default

reference

 

 

failover mode and array

 

 

 

commpath properties to the

 

 

 

values for PowerPath:

 

 

 

navicli -h hostname

 

 

 

failovermode 1

 

 

 

navicli -h hostname

 

 

 

arraycommpath 1

 

 

 

where hostname is the IP

 

 

 

address or network name of an

 

 

 

SP in the storage system.

 

 

 

Go to step 15.

 

 

 

 

 

PowerPath Checklist — New Windows Server and Existing Storage System Without Boot Disk

7-19

Page 277
Image 277
EMC 69001166 manual CX-Series or, Open, use the following Go to step