Windows Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

5

Server

Install the Navisphere Host Agent or Navisphere Server Utility and the

CX-Series Server

 

Install Host

Navisphere CLI.

Software for Windows

 

 

installation guide

 

Agent or Server

For a CX500i storage system

 

 

 

Utility

Reboot server either after the Host Agent installation is complete or when

 

 

 

 

 

 

the Server Utility dialog prompts you to reboot.

 

 

 

If you do not reboot before you run the Microsoft iSCSI Software Initiator to

 

 

 

configure iSCSI NIC initiators, the initiators will not log in to the storage

 

 

 

system.

 

 

 

 

 

6

Server

If the server will be a SnapView production or secondary host, install the

CX-Series Server

 

Install admsnap

admsnap utility.

Software for Windows

 

 

installation guide

 

and/or admhost

If the server has LUNs that will participate in a SAN Copy session, install

 

 

 

 

the admhost utility.

 

 

 

 

 

7

Fibre Channel

For a Fibre Channel SAN

Rails, cabinet, and

 

Switches

Install Fibre Channel switches, if not already installed.

switch documentation

 

Install

 

 

 

 

 

 

Connect a cable from each host HBA port to a switch port.

 

 

 

Checkpoint - Verify the HBA connection to the switch by checking the

 

 

 

LED(s) for the switch port connected to the HBA port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the HBA is logged

 

 

 

in to the switch port.

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off, which

 

 

 

indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

 

 

8

Storage System

Install the storage system in the cabinet, if not already installed.

Rails and cabinet

 

Install

 

documentation

 

 

 

 

 

 

 

9

Storage System

Cable the storage-system management port on each SP to the network

Storage-system setup

 

Cable

from which you will manage the storage system.

guide

 

 

 

 

management

 

 

 

ports

 

 

 

 

 

 

7-8

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 266
Image 266
EMC 69001166 manual For a CX500i storage system, Fibre Channel For a Fibre Channel SAN, Management Ports