Windows Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

13

Server With

For NICs

Storage-system setup

 

CX500i Storage

Use Microsoft iSCSI Software Initiator on the server to configure the iSCSI

guide

 

System

initiators for each NIC port.

 

 

Configure server

 

 

 

 

 

iSCSI initiator

For iSCSI HBAs

 

 

ports

Use QLogic SANsurfer to configure the network parameters for each HBA

 

 

 

 

 

 

port.

 

 

 

 

 

14

Storage System

Use Navisphere Manager to define a global administrator and domain (if

Navisphere security

 

Set up security

not already defined) and any additional users.

administrator’s guide

 

 

and Navisphere

 

 

 

 

 

 

Manager online help

 

 

 

 

15

Storage System

Use the following Navisphere CLI commands to set the following default

Navisphere CLI

 

Set Properties for

storage-system properties:

reference

 

 

 

 

PowerPath

navicli -h hostname systemtype -config 3

 

 

 

navicli -h hostname failovermode 1

 

 

 

navicli -h hostname arraycommpath 1

 

 

 

where hostname is the IP address or network name of an SP in the storage

 

 

 

system.

 

 

 

 

 

16

FIbre Channel

For a Fibre Channel SAN

Fibre Channel switch

 

Switches

Zone the Fibre Channel switches to provide a path from each HBA port

management

 

Zone additional

documentation

 

(host initiator) to the appropriate SPs.

 

 

 

paths

 

 

 

 

If SAN Copy, MirrorView, or MirrorView/A is installed, create any required

 

 

 

zones.

 

 

 

Checkpoint - Use switch management software to verify the switch

 

 

 

connections to the storage system.

 

 

 

 

 

17

Server

Restart the Host Agent or run the Navisphere Server Utility, then use the

Storage-system setup

 

Make target SPs

Disk Management tool to scan for disks.

guide and Windows

 

 

documentation

 

available

If the disks are not visible, scan for them once more.

 

 

 

 

Checkpoint - Use Navisphere Manager’s Connectivity Status dialog box to

Navisphere Manager

 

 

verify that each HBA or NIC is registered with the storage system.

administrator’s guide

 

 

 

and online help

 

 

 

 

18

Storage System

If you have optional SAN Copy, SnapView, MirrorView/A, and/or MirrorView

Storage-system setup

 

Install optional

/S software that you ordered, install its enabler.

guide and Navisphere

 

 

Manager administrator’s

 

software

 

 

 

guide and online help

 

 

 

 

 

 

 

7-10

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 268
Image 268
EMC 69001166 manual ISCSI initiator, Paths, Install optional