Solaris Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

9

Storage System

Connect the storage system to the switch or HBA ports.

Storage-system setup

 

Cable to switch or

 

guide.

 

 

 

 

server and LAN

Checkpoint - For a SAN, verify the storage-system connections to the

 

 

 

switch by checking the LED(s) for the switch port connected to each SP

 

 

 

port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the SP is logged

 

 

 

in to the switch port.

 

 

 

For a 2-Gigabit switch - One of the following:

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off,

 

 

 

which indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

Cable each SP to the LAN connected to the hosts from which you will

 

 

 

manage the storage system.

 

 

 

 

 

10

Storage System

Use Navisphere Manager to define a global administrator and domain (if

Navisphere security

 

Set up security

not already defined) and any additional users.

administrator’s guide

 

 

and Navisphere

 

 

 

 

 

 

Manager online help

 

 

 

 

11

Storage System

Use the following the following Navisphere CLI commands to set the

Navisphere CLI

 

Set Properties

following default storage-system properties to the values for PowerPath:

reference

 

 

 

 

for PowerPath

navicli -h hostname systemtype -config 3

 

 

 

navicli -h hostname failovermode 1

 

 

 

navicli -h hostname arraycommpath 1

 

 

 

navicli -h hostname unitserialnumber lun (only for server in a Sun

 

 

 

Cluster; it must left at the default setting for all other cases)

 

 

 

where hostname is the IP address or network name of an SP in the

 

 

 

storage system.

 

 

 

 

 

12

Switches

For a SAN

Switch management

 

Zone

Zone the switches to provide a path from each HBA port (host initiator) to

documentation

 

 

 

 

the appropriate SPs.

 

 

 

If SAN Copy, MirrorView, or MirrorView/A is installed, create any required

 

 

 

zones.

 

 

 

Checkpoint - Use switch management software to verify the switch

 

 

 

connections to the storage system.

 

 

 

 

 

5-10

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 206
Image 206
EMC 69001166 manual Set up security