HP-UX Installation Checklist

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Reference Document

 

 

 

 

 

 

 

 

 

9

Storage System

Connect the storage system to the switch or HBA ports.

Storage-system setup

 

 

 

Cable to switch or

Checkpoint - For a SAN, verify the storage-system connections to the

guide

 

 

 

 

 

 

 

server and LAN

 

 

 

 

 

switch by checking the LED(s) for the switch port connected to each SP

 

 

 

 

 

port.

 

 

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the SP is logged in

 

 

 

 

 

to the switch port

 

 

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off, which

 

 

 

 

 

indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

 

 

Cable each SP to the LAN connected to the hosts from which you will

Storage-system setup

 

 

 

 

manage the storage system.

guide

 

 

 

 

 

 

 

 

 

10

Storage System

Use Navisphere Manager to define a global administrator and domain (if

Navisphere security

 

 

 

Set up security

not already defined) and any additional users.

administrator’s guide

 

 

 

 

 

and Navisphere

 

 

 

 

 

 

 

 

 

 

 

 

Manager online help

 

 

 

 

 

 

 

 

 

11

Storage System

Use the following Navisphere CLI commands to set the storage-system

Navisphere CLI

 

 

 

Set properties for

properties:

reference

 

 

 

 

 

 

 

 

 

PowerPath

navicli -h hostname failovermode 1

 

 

 

 

 

navicli -h hostname arraycommpath 1

 

 

 

 

 

where hostname is the IP address or network name of an SP in the storage

 

 

 

 

 

system.

 

 

 

 

 

 

 

 

 

 

12

Switches

For a SAN

Switch management

 

 

 

Zone

Zone the switches to provide a path from each host initiator to an SP.

documentation

 

 

 

 

Checkpoint - Use switch management software to verify the switch

 

 

 

 

 

connections to the storage system.

 

 

 

 

 

 

 

 

 

 

13

Server

Make sure that each HBA sees only the targets (SPs) to which it is zoned

HP-UX documentation

 

 

 

Make target SPs

with the following HP-UX commands:

 

 

 

 

available

ioscan -fnC disk

 

 

 

 

 

insf -e

 

 

 

 

 

Verify that HP-UX sees device entries for all LUNS with the following

 

 

 

 

 

HP-UX command:

 

 

 

 

 

ioscan -fnC disk

 

 

 

 

 

 

 

 

 

PowerPath Checklist - New HP-UX Server and New Storage System

2-9

Page 59
Image 59
EMC 69001166 manual Set up security