AIX Installation Checklists

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

11

Server

For a 2-Gbit switch - One of the

For a 2-Gbit switch - One of the

 

 

Cable additional

following:

following:

 

 

 

 

 

 

or replacement

• The left LED is green and the

• The left LED is green and the

 

 

HBAs to switches

right LED is off, which indicates

right LED is off, which indicates

 

 

or storage

that a 1-Gbit SP port is logged

that a 1-Gbit SP port is logged

 

 

system (cont.)

in to the switch port.

in to the switch port.

 

 

 

• For a DS-xxB2 switch, both

• For a DS-xxB2 switch, both

 

 

 

LEDs are green, which

LEDs are green, which

 

 

 

indicates that a 2-Gbit HBA

indicates that a 2-Gbit HBA

 

 

 

port is logged in to the switch

port is logged in to the switch

 

 

 

port.

port.

 

 

 

• For a DS-xxM2 switch, the left

• For a DS-xxM2 switch, the left

 

 

 

LED is blue and the right LED

LED is blue and the right LED

 

 

 

is off, which indicates that a

is off, which indicates that a

 

 

 

2-Gbit HBA port is logged in to

2-Gbit HBA port is logged in to

 

 

 

the switch port.

the switch port.

 

 

 

 

 

 

12

Switches

For a SAN

For a SAN

Switch management

 

Zone for

❑ Zone the switches to provide a

❑ Zone the switches to provide a

documentation

 

 

 

additional HBAs

path from each additional HBA

path from each additional HBA

 

 

 

port (host initiator) to the

port (host initiator) to the

 

 

 

appropriate SPs.

appropriate SPs.

 

 

 

❑ Checkpoint - Use switch

❑ Checkpoint - Use switch

 

 

 

management software to verify

management software to verify

 

 

 

the switch connections to the

the switch connections to the

 

 

 

storage system.

storage system

 

 

 

 

 

 

13

Server

❑ Download the following command

❑ Download the following command

AIX documentation

 

Make target SPs

from ftp://ftp.emc.com/pub/elab/

from ftp://ftp.emc.com/pub/elab/

 

 

powerpath/aix and execute it:

powerpath/aix and execute it:

 

 

available

 

 

 

 

 

 

 

emc_cfgmgr.sh

emc_cfgmgr.sh

 

 

 

❑ Checkpoint - Verify that AIX sees

❑ Checkpoint - Verify that AIX sees

 

 

 

LUNZ devices with the following

LUNZ devices with the following

 

 

 

AIX command:

AIX command:

 

 

 

lscfg grep LUNZ

lscfg grep LUNZ

 

 

 

If AIX does not see LUNZ devices

If AIX does not see LUNZ devices

 

 

 

• Verify that arraycommpath is

• Verify that arraycommpath is

 

 

 

set to 1 as described in step 9.

set to 1 as described in step 9.

 

 

 

• Execute the following AIX

• Execute the following AIX

 

 

 

command:

command:

 

 

 

emc_cfgmgr.sh

emc_cfgmgr.sh

 

 

 

 

 

 

1-36

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 46
Image 46
EMC 69001166 manual Zone for, Port host initiator to Appropriate SPs Checkpoint Use switch