Solaris Installation Checklists

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

With Access Logix

Reference Document

 

 

 

 

 

 

 

 

20 Server

For a server with VERITAS VxVM V3.1.1 or below

VERITAS VxVM

 

 

VERITAS VxVM

Before you reboot the server, edit the /etc/rcS.d/S24powerstartup file to

documentation and

 

 

EMC manual on

 

 

 

add the following two lines to the bottom of the file after the last fi

 

 

 

installing and

 

 

 

character:

 

 

 

configuring EMP

 

 

 

/etc/powermt set volume_open_policy=firstpath

 

 

 

power devices with

 

 

 

echo "PowerPath:powermt set volume_open_policy=firstpath"

Solaris applications

 

 

 

 

 

 

 

On the next reboot, the first path policy used by CLARiiON storage

 

 

 

 

systems will take effect.

 

 

 

 

For a server with VERITAS VxVM V3.2 or above

 

 

 

 

Issue the following command:

 

 

 

 

vxddladm addjbod vid=DGC pagecode 0x83 offset=8 length=16

 

 

 

 

You need to issue this command just once and it will take effect on the next

 

 

 

 

reboot.

 

 

 

 

 

 

 

 

You are now ready to set up any optional software, such as SnapView or MirrorView, on the storage system.

PowerPath Checklist — Existing Solaris Server and New Storage System

5-31

Page 227
Image 227
EMC 69001166 manual Server For a server with Veritas VxVM V3.1.1 or below, Installing Character Configuring EMP