Windows Installation Checklists

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

 

 

 

 

 

7

CX-Series or

For existing HBAs

 

 

Navisphere Manager

 

 

 

FC4700-Series

An existing HBA is one that is

 

 

administrator’s guide

 

 

 

Storage System

 

 

and online help

 

 

 

registered with the storage system.

 

 

 

 

 

Set properties for

 

 

 

 

 

 

Use Navisphere Manager’s

 

 

 

 

 

 

PowerPath

Failover Setup Wizard (selected

 

 

 

 

 

 

(cont.)

 

 

 

 

 

 

from the Tools menu on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

toolbar) to set the following

 

 

 

 

 

 

 

storage-system properties for the

 

 

 

 

 

 

 

server’s existing HBA ports

 

 

 

 

 

 

 

(initiators):

 

 

 

 

 

 

 

Initiator Type to CLARiiON Open

 

 

 

 

 

 

 

Failover mode to 1

 

 

 

 

 

 

 

Array commpath to Enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

8

FC4500 Storage

Connect a computer to the serial

Connect a computer to the serial

Storage-system setup

 

 

 

System

port on the storage system.

port on the storage system.

guide

 

 

 

Set properties for

For new HBAs

For any HBAs

Navisphere CLI

 

 

 

PowerPath

 

 

 

reference

 

 

 

 

From the computer connected to

From the computer connected to

 

 

 

 

 

 

 

 

 

the storage system’s serial port,

the storage system’s serial port,

 

 

 

 

 

use the following Navisphere CLI

use the following Navisphere CLI

 

 

 

 

 

command to determine the

command to determine the

 

 

 

 

 

default storage-system type:

default storage-system type:

 

 

 

 

 

navicli -np -d device

navicli -np -d device

 

 

 

 

 

systemtype

systemtype

 

 

 

 

 

where device is the name of the

where device is the name of the

 

 

 

 

 

computer port connected to the

computer port connected to the

 

 

 

 

 

storage-system serial port (for

storage-system serial port (for

 

 

 

 

 

example, com1).

example, com1).

 

 

 

 

 

If the default storage-system

If the default storage-system

 

 

 

 

 

system type is not 3 (CLARiiON

system type is not 3 (CLARiiON

 

 

 

 

 

Open), use the following

Open), use the following

 

 

 

 

 

Navisphere CLI command to set

Navisphere CLI command to set

 

 

 

 

 

it to 3:

it to 3:

 

 

 

 

 

navicli -np -d device

navicli -np -d device

 

 

 

 

 

systemtype -config 3

systemtype -config 3

 

 

 

 

 

CAUTION The above command

CAUTION The above command

 

 

 

 

 

reboots both SPs at the same

reboots both SPs at the same time.

 

 

 

 

 

time.

 

 

 

 

 

 

 

 

 

 

 

 

PowerPath Checklist — Existing Windows Server and Existing Storage System

7-49

Page 307
Image 307
EMC 69001166 manual CX-Series or For existing HBAs, An existing HBA is one that is