NetWare Installation Checklists

PowerPath Checklist — New NetWare Server and Existing Storage System

Tasks highlighted with grey in the checklist should be completed before the service provider arrives.

The Without Access Logix column does not apply to CX300, CX500, and

CX700 storage systems because they ship from the factory with the Access

Logix enabler installed.

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

 

 

1

Server

Install HBAs.

Install HBAs.

HBA documentation

 

Install HBAs and

 

CAUTION Do not connect cables

 

CAUTION Do not connect cables

(see URL on page 4-4)

 

driver

 

to the HBAs until you are told to

 

to the HBAs until you are told to

 

 

 

 

do so later in this procedure.

 

do so later in this procedure.

 

 

 

Verify HBA BIOS settings.

 

 

 

 

 

 

 

 

 

 

Install HBA driver.

Install HBA driver.

 

 

 

 

 

 

 

 

 

 

2

Server

Set the HBA driver parameters to

Set the HBA driver parameters to

Host connectivity guide

 

Set HBA driver

 

the values required for CLARiiON

 

the values required for CLARiiON

and HBA documentation

 

 

and PowerPath.

 

and PowerPath.

(see URL on page 4-4)

 

parameters

 

 

 

 

 

 

 

 

 

 

 

CAUTION Using improper

 

CAUTION Using improper

 

 

 

 

settings can cause erratic failover

 

settings can cause erratic failover

 

 

 

 

behavior, such as greatly

 

behavior, such as greatly

 

 

 

 

increased I/O delays.

 

increased I/O delays.

 

 

 

 

 

 

 

3

Server

Make sure the SCSISAN.CDM

Make sure the SCSISAN.CDM

NetWare documentation

 

Install PowerPath

 

module is not installed.

 

module is not installed.

 

 

 

 

 

 

 

 

 

Install PowerPath.

Install PowerPath.

PowerPath release

 

 

 

Note After PowerPath is installed

 

Note After PowerPath is installed

notes and PowerPath for

 

 

 

 

NetWare installation and

 

 

 

on a NetWare 6 server, a device

 

on a NetWare 6 server, a device

administrator’s guide

 

 

 

named EMC PowerPath Control

 

named EMC PowerPath Control

PowerPath product

 

 

 

Device appears under

 

Device appears under

guide

 

 

 

ConsoleOne > Tools > Disk

 

ConsoleOne > Tools > Disk

 

 

 

 

Management > Devices.This

 

Management > Devices.This

 

 

 

 

device is always inactive and is

 

device is always inactive and is

 

 

 

 

unavailable for I/O.

 

unavailable for I/O.

 

 

 

 

 

 

 

 

4-12

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 170
Image 170
EMC 69001166 Verify HBA Bios settings Install HBA driver, Module is not installed Install PowerPath PowerPath release