AIX Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

7

Server

Make sure the HBA driver parameters are set to the values required for

Host connectivity guide

 

Set HBA driver

CLARiiON and PowerPath.

 

 

 

 

 

parameters

CAUTION Using improper settings can cause erratic failover behavior,

 

 

 

such as greatly increased I/O delays.

 

 

 

 

 

8

Server

Insert the PowerPath installation CD and mount it.

PowerPath Release

 

Install PowerPath

Install PowerPath from the command line or using SMIT.

Notes and PowerPath

 

for UNIX installation and

 

 

 

 

 

 

administrator’s guide

 

 

Register PowerPath.

 

 

 

Install any PowerPath patches from the Software downloads page on the

 

 

 

EMC Powerlink website:

 

 

 

http://powerlink.emc.com

 

 

 

 

 

9

Storage System

Install the storage system in the cabinet, if not already installed.

Rails and cabinet

 

Install

 

documentation

 

 

 

 

 

 

 

10

Storage System

Install the Navisphere Initialization Utility on a non-AIXhost on the same

Storage-system setup

 

Initialize and

subnet as the storage-system management ports.

guide

 

 

 

 

install software

Use the Navisphere Initialization Utility to initialize the storage system.

 

 

enablers

If you have SAN Copy, SnapView, and/or MirrorView software, install their

Navisphere Manager

 

 

 

 

enablers.

administrator’s guide

 

 

 

and online help

 

 

 

 

11

Storage System

Connect the storage system to the switch or HBA ports.

Storage-system setup

 

Cable to switch

 

guide.

 

 

 

 

or server and

Checkpoint - For a SAN, verify the storage-system connections to the

Switch documentation

 

LAN

 

switch by checking the LED(s) for the switch port connected to each SP

 

 

 

 

 

 

port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the SP is logged

 

 

 

in to the switch port.

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off,

 

 

 

which indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

Cable each SP to the LAN connected to the hosts from which you will

Storage-system setup

 

 

manage the storage system.

guide.

 

 

 

 

1-24

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 34
Image 34
EMC 69001166 manual Or server