EMC 69001166 manual Create DOS, Partition for

Models: 69001166

1 330
Download 330 pages 55.9 Kb
Page 152
Image 152

Linux Installation Checklist

Task

 

With Access Logix

Reference Document

 

 

 

 

13

Server

Download the CLARiiON DMP driver to the server from Services on the

VERITAS Volume

 

Install the

VERITAS website.

Manager documentation

 

 

 

 

CLARiiON DMP

Use the rpm command to install the CLARiiON DMP driver on the server.

 

 

driver

 

 

 

 

Note Until rootdg is created (part of vxinstall command) on at least one

 

 

 

disk, DMP displays an error message looking for the config daemon.

 

 

 

 

 

14

Storage System

Use the following Navisphere CLI commands to set the default

navicli man page or

 

Set the system

storage-system type and failover mode properties:

Navisphere CLI reference

 

 

 

 

type and failover

navicli -h sp systemtype -config 3

 

 

mode

navicli -h sp storagegroup -sethost -host linux_host -failovermode 2

 

 

 

 

 

 

where

 

 

 

sp is the IP address or network name of the SP in the storage system.

 

 

 

linux_host is the name of the Linux server

 

 

 

 

 

15

Server

Use the fdisk command to create at least one DOS partition for Volume

Linux documentation

 

Create DOS

Manager.

 

 

 

 

 

partition for

 

 

 

Volume Manager

 

 

 

 

 

 

16

Server

Reboot the server using the reboot command

Linux documentation

 

Reboot

•to make LUNs available to Linux

 

 

 

•to make LUNs accessible via both SPs

 

 

 

Important If you do not set the failover mode to 2, you will see only half of the

 

 

 

expected paths to the SPs.

 

 

 

 

 

17

Server

Run vxinstall to configure Volume Manager and place at least one LUN

VERITAS Volume

 

Configure

under VxVM control.

Manager documentation

 

 

 

 

Volume Manager

 

 

 

 

 

 

18

Server

For VXVM 3.5 or higher

VERITAS Volume

 

Verify DMP

Log into VERITAS Enterprise Administrator (VEA).

Manager documentation

 

 

 

installation

 

 

 

 

Click the host name for the server.

 

 

 

Click disks.

 

 

 

Click a device that you know belongs to the CLARiiON storage system.

 

 

 

Click the paths tab for that device.

 

 

 

Verify that the device has primary and secondary paths to it.

 

 

 

Verify the state of the device (enabled or disabled).

 

 

 

 

 

3-44

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 152
Image 152
EMC 69001166 manual Create DOS, Partition for