EMC 69001166 manual DMP Checklist New HP-UX Server and New Storage System, SPs

Models: 69001166

1 330
Download 330 pages 55.9 Kb
Page 98
Image 98

HP-UX Installation Checklist

DMP Checklist - New HP-UX Server and New Storage System

Complete the tasks highlighted with grey in the checklist before the service provider arrives.

Task

 

With Access Logix

Reference Document

 

 

 

 

1

Server

Install the HBAs.

HBA documentation

 

Install HBAs,

Connect a cable from each host HBA port to a switch port or an SP port.

 

 

drivers, cables

 

 

 

Install the HBA driver.

 

 

 

 

 

2

Server

Set the HBA driver parameters to the values required for CLARiiON.

Host connectivity guide

 

Set HBA driver

Caution Using improper settings can cause erratic failover behavior, such

and HBA

 

documentation

 

parameters

 

as greatly increased I/O delays.

 

 

 

 

 

 

 

Reboot the server to complete the installation of the drivers.

 

 

 

Checkpoint — For a SAN, verify the server connections to the switch by

 

 

 

checking the LED(s) for the switch port connected to each HBA port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the HBA is logged

 

 

 

in to the switch port.

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

• Only the left LED is green, which indicates that a 1-Gbit HBA port is

 

 

 

logged in to the switch port.

 

 

 

• Both LEDs are green, which indicates that a 2-Gbit HBA port is logged in

 

 

 

to the switch port.

 

 

 

 

 

3

Switches

Verify that the servers and SPs are connected to the switch.

Documentation that

 

Connect servers

 

ships with the switches

 

and SPs

 

 

 

 

 

 

4

Switches

For a SAN

Switch documentation

 

Zone

Zone the switches to provide a path from each host initiator to an SP.

 

 

 

 

 

5

Server

Make sure each HBA sees only the targets (SPs) to which it is zoned with

HP-UX documentation

 

Make target SPs

the following HP-UX commands:

 

 

available

ioscan -fnC disk

 

 

 

insf -e

 

 

 

Checkpoint - Reverify that HP-UX sees device entries for all LUNS with

 

 

 

the following HP-UX command:

 

 

 

ioscan -fnC disk

 

 

 

 

 

2-48

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 98
Image 98
EMC 69001166 manual DMP Checklist New HP-UX Server and New Storage System, SPs