Windows Installation Checklists

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

 

 

 

 

 

 

12

Server

Reinstall HBA driver.

Reinstall HBA driver.

HBA documentation

 

 

 

Set HBA driver

 

 

 

 

(see URL on 7-5)

 

 

 

 

 

 

 

 

 

 

 

properties

Set the HBA driver parameters to

Set the HBA driver parameters to

 

 

 

 

 

 

 

 

 

 

 

the values required for

the values required for

 

 

 

 

 

 

CLARiiON.

CLARiiON.

 

 

 

 

 

 

CAUTION Using improper

CAUTION Using improper

 

 

 

 

 

 

settings can cause erratic failover

settings can cause erratic failover

 

 

 

 

 

 

behavior, such as greatly

behavior, such as greatly

 

 

 

 

 

 

increased I/O delays.

increased I/O delays.

 

 

 

 

 

 

 

 

 

 

 

13

Storage System

For a CX-Series or FC4700-Series

For a CX-Series or FC4700-Series

Navisphere Manager

 

 

 

Set properties for

storage system

storage system

administrator’s guide

 

 

 

PowerPath

Use Navisphere Manager’s

Use the following Navisphere CLI

and online help or

 

 

 

Navisphere CLI

 

 

 

 

 

 

 

 

 

Failover Setup Wizard (selected

command to determine the

reference

 

 

 

 

 

from the Tools menu on the

default storage-system type:

 

 

 

 

 

 

 

 

 

 

 

toolbar) to set the following

navicli -h hostname systemtype

 

 

 

 

 

 

storage-system properties for the

 

 

 

 

 

 

where hostname is the IP

 

 

 

 

 

 

server’s HBA ports (initiators):

 

 

 

 

 

 

Initiator Type to CLARiiON Open

address or network name of an

 

 

 

 

 

 

SP in the storage system.

 

 

 

 

 

 

Failover mode to 1

 

 

 

 

 

 

If the default storage-system

 

 

 

 

 

 

Array commpath to Enabled

 

 

 

 

 

 

system type is not 3 (CLARiiON

 

 

 

 

 

 

 

Open), use the following

 

 

 

 

 

 

 

Navisphere CLI command to set

 

 

 

 

 

 

 

it to 3:

 

 

 

 

 

 

 

navicli -h hostname systemtype

 

 

 

 

 

 

 

-config 3

 

 

 

 

 

 

 

CAUTION The above command

 

 

 

 

 

 

 

reboots both SPs at the same

 

 

 

 

 

 

 

time.

 

 

 

 

 

 

 

Use the following Navisphere CLI

Navisphere CLI

 

 

 

 

 

 

commands to set the default

reference

 

 

 

 

 

 

failover mode and array

 

 

 

 

 

 

 

commpath properties to the

 

 

 

 

 

 

 

values for PowerPath:

 

 

 

 

 

 

 

navicli -h hostname

 

 

 

 

 

 

 

failovermode 1

 

 

 

 

 

 

 

navicli -h hostname

 

 

 

 

 

 

 

arraycommpath 1

 

 

 

 

 

 

 

where hostname is the IP

 

 

 

 

 

 

 

address or network name of an

 

 

 

 

 

 

 

SP in the storage system.

 

 

 

 

 

 

 

 

 

 

 

PowerPath Checklist — New Windows Server and Existing Storage System With Boot Disk

7-29

Page 287
Image 287
EMC 69001166 manual Reinstall HBA driver HBA documentation, Values required for CLARiiON, Online help or Navisphere CLI