Tru64 UNIX Installation Checklist

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

 

 

Reference Document

 

 

 

 

 

 

 

 

 

3

Switches

Zone the switches to provide a single path from one

Switch management documentation

 

 

 

Zone single path to

HBA (host initiator) to default SP owner of the boot disk

 

 

 

 

SP

LUN in the storage system.

 

 

 

 

 

Do note zone more than one path to the storage system

 

 

 

 

 

at this point in the installation procedure. The

 

 

 

 

 

installation my fail if both SPs are visible to Tru64 UNIX.

 

 

 

 

 

You can zone multiple paths later in the installation

 

 

 

 

 

procedure.

 

 

 

 

 

 

 

Checkpoint — Verify that the HBA connection is visible.

Host connectivity guide for Tru64 UNIX

 

 

 

 

If it is not visible, execute the init command at the

and Tru64 UNIX documentation

 

 

 

 

 

 

 

 

 

server’s console.

 

 

 

 

 

 

 

 

 

 

 

 

4

Storage System

Determine the port name and node name of each HBA

Host connectivity guide for Tru64 UNIX

 

 

 

Set connection

connected to the storage system.

 

 

 

 

properties

Use Navisphere Manager to register the connection for

Navisphere Manager administrator’s

 

 

 

 

 

 

 

 

each HBA with the following Initiator Record properties:

guide and online help

 

 

 

 

Property

Value

 

 

 

 

 

Initiator Type

Compaq/Tru64

 

 

 

 

 

ArrayCommPath

Selected

 

 

 

 

 

Failover Mode

0

 

 

 

 

 

 

Unit Serial Number

Array

 

 

 

 

 

 

 

 

 

 

5

Storage System

CAUTION The RAID Group for the boot LUN must consist of

Navisphere Manager administrator’s

 

 

 

Bind Boot LUN

Fibre Channel disks (not ATA disks).

guide and online help

 

 

 

 

Use Navisphere Manager to create a RAID Group for

 

 

 

 

 

the LUN that will be the system disk and bind that LUN.

 

 

 

 

 

Create a Storage Group for the boot LUN.

 

 

 

 

 

After the binding of the boot LUN is completed, use

 

 

 

 

 

Navisphere Manager to connect the server to its

 

 

 

 

 

Storage Group.

 

 

 

 

 

 

 

 

 

 

 

 

Checklist - New Tru64 UNIX Server and New Storage System With Boot Disk

6-7

Page 255
Image 255
EMC 69001166 manual With Access Logix Reference Document Switches, Bind Boot LUN