EMC 69001166 manual Reboot

Models: 69001166

1 330
Download 330 pages 55.9 Kb
Page 100
Image 100

HP-UX Installation Checklist

Task

 

With Access Logix

Reference Document

 

 

 

 

10

Server

Log in as root and restart the Navisphere Host Agent with the following

CX-Series Server

 

Make LUNs

HP-UX commands:

Software for HP-UX

 

 

Installation Guide

 

visible

/sbin/init.d/agent stop

 

 

 

 

/sbin/init.d/agent start

 

 

 

Checkpoint - Verify that HP-UX can recognize these LUNs with the

HP-UX documentation

 

 

following HP-UX commands:

 

 

 

ioscan -fnC disk

 

 

 

insf -e

 

 

 

If HP-UX does not recognize any LUNs, verify the connection to the

 

 

 

Storage Group.

 

 

 

Checkpoint - Reverify that HP-UX sees device entries for all LUNS with

 

 

 

the following HP-UX command:

 

 

 

ioscan -fnC disk

 

 

 

 

 

11

Storage System

Plan your monitoring configuration.

Navisphere Manager

 

Set up Event

Use Navisphere Manager to set user options, create templates, and set up

administrator’s guide

 

and online help

 

Monitor

 

your monitoring configuration.

 

 

 

 

 

 

 

 

12

Server

Download the CLARiiON DMP driver to the server from Services on the

 

 

Install the

VERITAS website.

 

 

 

 

 

CLARiiON DMP

Use the swinstall command to install the CLARiiON DMP driver on the

VERITAS Volume

 

driver

server.

Navisphere Manager

 

 

 

 

Note Until rootdg is created (part of vxinstall command) on at least one

documentation

 

 

 

 

 

disk, DMP displays an error message looking for the config daemon.

 

 

 

 

 

13

Server

Reboot the server using the reboot command

VERITAS Volume

 

Reboot

• to make LUNs available to the OS

Navisphere Manager

 

documentation

 

 

• to make LUNs accessible via both SPs

 

 

 

 

 

Important If you do not set the failover mode to 2, you will see only half of the

 

 

 

expected paths to the SPs.

 

 

 

 

 

14

Server

Run vxinstall to configure Volume Manager and place at least one LUN

VERITAS Volume

 

Configure

under VxVM control.

Navisphere Manager

 

 

documentation

 

Volume Manager

 

 

 

 

 

 

 

 

2-50

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 100
Image 100