Windows Installation Checklists

Task

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

13 Storage System

For an FC4500 storage system

For an FC4500 storage system

Storage-system setup

Set properties for

Connect a computer to the serial

Connect a computer to the serial

guide

 

PowerPath

port on the storage system.

port on the storage system

 

(cont.)

 

 

 

 

From the computer connected to

From the computer connected to

Navisphere CLI

 

the storage system’s serial port,

the storage system’s serial port,

reference

 

use the following Navisphere CLI

use the following Navisphere CLI

 

 

commands to set the following

command to determine the

 

 

storage-system properties for the

default storage-system type:

 

 

server’s HBA ports (initiators):

navicli -np -d device

 

 

 

 

 

navicli -np -d device

systemtype

 

 

storagegroup -sethost -host

where device is the name of the

 

 

servername -type 3

 

 

computer port connected to the

 

 

navicli -np -d device

 

 

storage-system serial port (for

 

 

storagegroup -sethost -host

example, com1).

 

 

servername -failovermode 1

If the default storage-system

 

 

 

 

 

navicli -np -d device

system type is not 3 (CLARiiON

 

 

storagegroup -sethost -host

Open), use the following

 

 

servername -arraycommpath 1

Navisphere CLI command to set

 

 

where

it to 3:

 

 

navicli -np -d device

 

 

device is the name of the

 

 

systemtype -config 3

 

 

computer port connected to the

 

 

 

 

 

storage-system serial port (for

CAUTION The above command

 

 

example, com1).

reboots both SPs at the same

 

 

servername is the name of the

time.

 

 

server with the HBAs.

 

 

 

 

For an FC4500 storage system

Navisphere CLI

 

 

From the computer connected to

reference

 

 

 

 

 

the storage system’s serial port,

 

 

 

use the following Navisphere CLI

 

 

 

commands to set the following

 

 

 

default storage-system

 

 

 

properties:

 

 

 

navicli -np -d device

 

 

 

failovermode 1

 

 

 

navicli -np -d device

 

 

 

arraycommpath 1

 

 

 

where device is the name of the

 

 

 

computer port connected to the

 

 

 

storage-system serial port (for

 

 

 

example, com1).

 

 

 

 

 

7-30

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 288
Image 288
EMC 69001166 manual Reboots both SPs at the same Servername is the name