HP-UX Installation Checklist

Task

 

With Access Logix

Reference Document

 

 

 

 

19

Server

View the output of the powermt display dev=x every=2 command, and

PowerPath product

 

Test PowerPath

verify that

guide

 

 

 

 

with a license

• The state of the uncabled path(s) becomes “dead.”

 

 

key (cont.)

• I/O continues to the remaining path(s) to the LUN, indicating that the

 

 

 

 

 

 

path failover was successful, and PowerPath is working properly.

 

 

 

Reconnect the cable that you disconnected from the HBA.

 

 

 

If you did not follow the above steps exactly and caused any LUNs to

 

 

 

trespass, restore the LUNs to their original SP with the following PowerPath

 

 

 

command:

 

 

 

powermt restore

 

 

 

 

 

20

Server

Prepare the LUNs to receive data using the Logical Volume Manager

Host connectivity guide

 

Make LUNs

(LVM).

and HP-UX

 

available to

If HP-UX does not recognize any LUNs, verify the connection to the

documentation

 

 

 

HP-UX

 

 

Storage Group.

 

 

 

 

 

 

 

 

You are now ready to set up any optional software, such as SnapView or MirrorView, on the storage system.

2-32

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 82
Image 82
EMC 69001166 manual Verify that Guide, State of the uncabled paths becomes dead, Command Powermt restore Server, Lvm Hp-Ux