NetWare Installation Checklists

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

10

Server

Cable any additional HBA ports to

Cable any additional HBA ports to

Storage-system setup

 

Cable additional

 

the switch connected to the

 

the switch connected to the

guide.

 

 

storage system or to SP ports.

 

storage system or to SP ports.

 

 

HBAs to

 

 

 

 

 

 

 

 

 

 

switches or

Checkpoint - For a SAN, verify

Checkpoint - For a SAN, verify the

 

 

storage system

 

 

 

 

the HBA connections to the

 

HBA connections to the switch by

 

 

 

 

switch by checking the LED(s) for

 

checking the LED(s) for the switch

 

 

 

 

the switch port connected to each

 

port connected to each additional

 

 

 

 

additional HBA port.

 

HBA port.

 

 

 

 

For a 1-Gbit switch - LED is

 

For a 1-Gbit switch - LED is

 

 

 

 

green, which indicates that the

 

green, which indicates that the

 

 

 

 

HBA port is logged in to the

 

HBA port is logged in to the switch

 

 

 

 

switch port.

 

port.

 

 

 

 

For a 2-Gbit switch - One of the

 

For a 2-Gbit switch - One of the

 

 

 

 

following:

 

following:

 

 

 

 

• The left LED is green and the

 

• The left LED is green and the

 

 

 

 

right LED is off, which

 

right LED is off, which indicates

 

 

 

 

indicates that a 1-Gbit SP port

 

that a 1-Gbit SP port is logged in

 

 

 

 

is logged in to the switch port.

 

to the switch port.

 

 

 

 

• For a DS-xxB2 switch, both

 

• For a DS-xxB2 switch, both

 

 

 

 

LEDs are green, which

 

LEDs are green, which indicates

 

 

 

 

indicates that a 2-Gbit HBA

 

that a 2-Gbit HBA port is logged

 

 

 

 

port is logged in to the switch

 

in to the switch port.

 

 

 

 

port.

 

• For a DS-xxM2 switch, the left

 

 

 

 

 

 

 

 

 

 

• For a DS-xxM2 switch, the left

 

LED is blue and the right LED is

 

 

 

 

LED is blue and the right LED

 

off, which indicates that a 2-Gbit

 

 

 

 

is off, which indicates that a

 

HBA port is logged in to the

 

 

 

 

2-Gbit HBA port is logged in to

 

switch port.

 

 

 

 

the switch port.

 

 

 

 

 

 

 

 

11

Switches

For a SAN

For a SAN

Switch management

 

Zone for

Zone the switches to provide a

Zone the switches to provide a

documentation

 

 

 

additional HBAs

 

path from each additional HBA

 

path from each additional HBA port

 

 

 

 

port (host initiator) to the SPs.

 

(host initiator) to the SPs.

 

 

 

Checkpoint - Use switch

Checkpoint - Use switch

 

 

 

 

management software to verify

 

management software to verify the

 

 

 

 

the switch connections to the

 

switch connections to the storage

 

 

 

 

storage system.

 

system.

 

 

 

 

 

 

 

 

12

Server

Reboot the server.

Reboot the server.

 

 

Register

Checkpoint - Use Navisphere

 

 

Navisphere Manager

 

additional HBAs

 

 

 

with storage

 

Manager’s Connectivity Status

 

 

administrator’s guide

 

 

dialog box to verify that each new

 

 

and online help

 

system

 

 

 

 

 

HBA is registered with the

 

 

 

 

 

 

 

 

 

 

 

 

storage system.

 

 

 

 

 

 

 

 

 

 

PowerPath Checklist — Existing NetWare Server and Existing Storage System

4-35

Page 193
Image 193
EMC 69001166 manual HBA port is logged in to, Switch port Port, For a DS-xxB2 switch, both LEDs are green, which