HP-UX Installation Checklist

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Without Access Logix

 

Reference Document

 

 

 

 

 

 

 

 

 

 

 

 

10

Server

For a 2-Gbit switch - One of the

 

For a 2-Gbit switch - One of the

 

Switch documentation

 

 

 

Cable additional

following:

 

following:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HBAs to

• The left LED is green and the

 

• The left LED is green and the

 

 

 

 

 

switches or

right LED is off, which indicates

 

right LED is off, which indicates

 

 

 

 

 

storage system

that a 1-Gbit SP port is logged

 

that a 1-Gbit SP port is logged

 

 

 

 

 

(cont.)

in to the switch port.

 

in to the switch port.

 

 

 

 

 

 

• For a DS-xxB2 switch, both

 

• For a DS-xxB2 switch, both

 

 

 

 

 

 

LEDs are green, which

 

LEDs are green, which

 

 

 

 

 

 

indicates that a 2-Gbit HBA

 

indicates that a 2-Gbit HBA

 

 

 

 

 

 

port is logged in to the switch

 

port is logged in to the switch

 

 

 

 

 

 

port.

 

port.

 

 

 

 

 

 

• For a DS-xxM2 switch, the left

 

• For a DS-xxM2 switch, the left

 

 

 

 

 

 

LED is blue and the right LED

 

LED is blue and the right LED

 

 

 

 

 

 

is off, which indicates that a

 

is off, which indicates that a

 

 

 

 

 

 

2-Gbit HBA port is logged in to

 

2-Gbit HBA port is logged in to

 

 

 

 

 

 

the switch port.

 

the switch port.

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Switches

For a SAN

For a SAN

 

Switch management

 

 

 

Zone

❑ Zone the switches to provide a

❑ Zone the switches to provide a

 

documentation

 

 

 

 

 

 

 

 

 

path from each HBA port (host

 

path from each HBA port (host

 

 

 

 

 

 

initiator) to the appropriate SPs.

 

initiator) to the appropriate SPs.

 

 

 

 

 

 

❑ Checkpoint - Use switch

❑

Checkpoint - Use switch

 

 

 

 

 

 

management software to verify

 

management software to verify

 

 

 

 

 

 

the switch connections to the

 

the switch connections to the

 

 

 

 

 

 

storage system.

 

storage system.

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Server

❑ Make sure that each HBA sees

❑ Verify that each HBA sees only

 

HP-UX documentation

 

 

 

Make target SPs

only the targets (SPs) to which it

 

the targets (SPs) to which it is

 

 

 

 

 

available

is zoned with the following HP-UX

 

zoned with the HP-UX following

 

 

 

 

 

 

commands:

 

commands:

 

 

 

 

 

 

ioscan -fnC disk

 

ioscan -fnC disk

 

 

 

 

 

 

insf -e

 

insf -e

 

 

 

 

 

 

❑ Verify that HP-UX sees device

❑ Verify that HP-UX sees device

 

 

 

 

 

 

entries for all LUNS with the

 

entries for all LUNS with the

 

 

 

 

 

 

following HP-UX command:

 

following HP-UX command:

 

 

 

 

 

 

ioscan -fnC disk

❑

ioscan -fnC disk

 

 

 

 

 

 

❑ Log in as root and restart the

❑ Log in as root and restart the

 

CX-Series Server

 

 

 

 

Navisphere Host Agent with the

 

Navisphere Host Agent with the

 

Software for HP-UX

 

 

 

 

following HP-UX commands:

 

following HP-UX commands:

 

Installation Guide

 

 

 

 

/sbin/init.d/agent stop

 

/sbin/init.d/agent stop

 

 

 

 

 

 

/sbin/init.d/agent start

 

/sbin/init.d/agent start

 

 

 

 

 

 

 

 

 

 

 

 

 

PowerPath Checklist - Existing HP-UX Server and Existing Storage System

2-41

Page 91
Image 91
EMC 69001166 manual HBAs to, Entries for all Luns with, Following HP-UX command