HP-UX Installation Checklist

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Without Access Logix

 

Reference Document

 

 

 

 

 

 

 

 

 

 

 

 

10

Server

For a 2-Gbit switch - One of the

 

For a 2-Gbit switch - One of the

 

Switch documentation

 

 

 

Cable additional

following:

 

following:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HBAs to

• The left LED is green and the

 

• The left LED is green and the

 

 

 

 

 

switches or

right LED is off, which indicates

 

right LED is off, which indicates

 

 

 

 

 

storage system

that a 1-Gbit SP port is logged

 

that a 1-Gbit SP port is logged

 

 

 

 

 

(cont.)

in to the switch port.

 

in to the switch port.

 

 

 

 

 

 

• For a DS-xxB2 switch, both

 

• For a DS-xxB2 switch, both

 

 

 

 

 

 

LEDs are green, which

 

LEDs are green, which

 

 

 

 

 

 

indicates that a 2-Gbit HBA

 

indicates that a 2-Gbit HBA

 

 

 

 

 

 

port is logged in to the switch

 

port is logged in to the switch

 

 

 

 

 

 

port.

 

port.

 

 

 

 

 

 

• For a DS-xxM2 switch, the left

 

• For a DS-xxM2 switch, the left

 

 

 

 

 

 

LED is blue and the right LED

 

LED is blue and the right LED

 

 

 

 

 

 

is off, which indicates that a

 

is off, which indicates that a

 

 

 

 

 

 

2-Gbit HBA port is logged in to

 

2-Gbit HBA port is logged in to

 

 

 

 

 

 

the switch port.

 

the switch port.

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Switches

For a SAN

For a SAN

 

Switch management

 

 

 

Zone

Zone the switches to provide a

Zone the switches to provide a

 

documentation

 

 

 

 

 

 

 

 

 

path from each HBA port (host

 

path from each HBA port (host

 

 

 

 

 

 

initiator) to the appropriate SPs.

 

initiator) to the appropriate SPs.

 

 

 

 

 

 

Checkpoint - Use switch

Checkpoint - Use switch

 

 

 

 

 

 

management software to verify

 

management software to verify

 

 

 

 

 

 

the switch connections to the

 

the switch connections to the

 

 

 

 

 

 

storage system.

 

storage system.

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Server

Make sure that each HBA sees

Verify that each HBA sees only

 

HP-UX documentation

 

 

 

Make target SPs

only the targets (SPs) to which it

 

the targets (SPs) to which it is

 

 

 

 

 

available

is zoned with the following HP-UX

 

zoned with the HP-UX following

 

 

 

 

 

 

commands:

 

commands:

 

 

 

 

 

 

ioscan -fnC disk

 

ioscan -fnC disk

 

 

 

 

 

 

insf -e

 

insf -e

 

 

 

 

 

 

Verify that HP-UX sees device

Verify that HP-UX sees device

 

 

 

 

 

 

entries for all LUNS with the

 

entries for all LUNS with the

 

 

 

 

 

 

following HP-UX command:

 

following HP-UX command:

 

 

 

 

 

 

ioscan -fnC disk

ioscan -fnC disk

 

 

 

 

 

 

Log in as root and restart the

Log in as root and restart the

 

CX-Series Server

 

 

 

 

Navisphere Host Agent with the

 

Navisphere Host Agent with the

 

Software for HP-UX

 

 

 

 

following HP-UX commands:

 

following HP-UX commands:

 

Installation Guide

 

 

 

 

/sbin/init.d/agent stop

 

/sbin/init.d/agent stop

 

 

 

 

 

 

/sbin/init.d/agent start

 

/sbin/init.d/agent start

 

 

 

 

 

 

 

 

 

 

 

 

 

PowerPath Checklist - Existing HP-UX Server and Existing Storage System

2-41

Page 91
Image 91
EMC 69001166 manual HBAs to, Entries for all Luns with, Following HP-UX command