NetWare Installation Checklists

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

 

11

Server

Scan for LUNs with the following

Scan for LUNs with the following

NetWare documentation

 

Make target SPs

 

NetWare command:

NetWare command:

 

 

 

 

 

 

 

available

 

scan all luns

scan all luns

 

 

 

Checkpoint - Verify that each

Checkpoint - Verify the paths to

 

 

 

 

path has a LUNZ with the

each LUN with the following

 

 

 

 

following NetWare command:

NetWare command:

 

 

 

 

list devices

list devices

 

 

 

Stop and restart the Navisphere

Stop and restart the Navisphere

CX-Series Server

 

 

 

Host Agent or run the Navisphere

Host Agent or run the Navisphere

Software for NetWare

 

 

 

Server Utility.

Server Utility.

Installation Guide

 

 

 

 

 

 

12

Storage System

If the server will use an existing

 

Navisphere Manager

 

Configure

 

Storage Group, use Navisphere

 

administrator’s guide

 

 

Manager to connect the server to

 

and online help

 

 

 

 

 

 

 

the Storage Group.

 

 

 

 

If the server will use a new

 

 

 

 

 

Storage Group, use Navisphere

 

 

 

 

 

Manager to create RAID Groups,

 

 

 

 

 

bind LUNs, create the Storage

 

 

 

 

 

Group, and assign LUNs to the

 

 

 

 

 

Storage Group.

 

 

 

 

Use Navisphere Manager to

 

 

 

 

 

connect the server to the Storage

 

 

 

 

 

Group.

 

 

 

 

Reboot the server.

Reboot the server.

 

 

 

 

 

 

 

PowerPath Checklist — New NetWare Server and Existing Storage System

4-17

Page 175
Image 175
EMC 69001166 manual Path has a Lunz with, Server Utility Installation Guide, Group Reboot the server