NetWare Installation Checklists

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

 

11

Server

❑

Scan for LUNs with the following

❑ Scan for LUNs with the following

NetWare documentation

 

Make target SPs

 

NetWare command:

NetWare command:

 

 

 

 

 

 

 

available

 

scan all luns

scan all luns

 

 

 

❑

Checkpoint - Verify that each

❑ Checkpoint - Verify the paths to

 

 

 

 

path has a LUNZ with the

each LUN with the following

 

 

 

 

following NetWare command:

NetWare command:

 

 

 

 

list devices

list devices

 

 

 

❑ Stop and restart the Navisphere

❑ Stop and restart the Navisphere

CX-Series Server

 

 

 

Host Agent or run the Navisphere

Host Agent or run the Navisphere

Software for NetWare

 

 

 

Server Utility.

Server Utility.

Installation Guide

 

 

 

 

 

 

12

Storage System

❑

If the server will use an existing

 

Navisphere Manager

 

Configure

 

Storage Group, use Navisphere

 

administrator’s guide

 

 

Manager to connect the server to

 

and online help

 

 

 

 

 

 

 

the Storage Group.

 

 

 

 

❑ If the server will use a new

 

 

 

 

 

Storage Group, use Navisphere

 

 

 

 

 

Manager to create RAID Groups,

 

 

 

 

 

bind LUNs, create the Storage

 

 

 

 

 

Group, and assign LUNs to the

 

 

 

 

 

Storage Group.

 

 

 

 

❑ Use Navisphere Manager to

 

 

 

 

 

connect the server to the Storage

 

 

 

 

 

Group.

 

 

 

 

❑

Reboot the server.

❑ Reboot the server.

 

 

 

 

 

 

 

PowerPath Checklist — New NetWare Server and Existing Storage System

4-17

Page 175
Image 175