Solaris Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

1

Server

If you need additional HBAs to provide more paths to the storage system,

HBA documentation

 

Install additional

install these HBAs.

(see URL on

 

 

 

page 5-4)

 

HBAs

CAUTION Do not connect cables to the HBAs until you are told to do so

 

 

 

 

later in this procedure.

 

 

 

 

 

2

Server

If ATF or CDE is installed, then before continuing either remove it yourself

Removing ATF or

 

Remove ATF or

(see caution before this checklist) or arrange to have EMC Professional

CDE

 

Services remove it.

 

 

CDE

 

 

 

 

 

 

 

 

 

3

Server

If the following software is currently installed and not at the required

HBA documentation

 

Update Software

minimum revision (page 5-3), update it:

(see URL on

 

 

 

page 5-4)

 

 

• HBA driver (save the persistent bindings as you will need to add them to

 

 

 

the new driver.)

CX-Series Server

 

 

Navisphere Host Agent

Software for Solaris

 

 

Installation Guide

 

 

admsnap

 

 

 

 

 

 

 

4

Server

Make sure the HBA driver parameters, except for the persistent bindings,

Solaris host

 

Set HBA driver

are set to the values required for CLARiiON and PowerPath.

connectivity guide

 

 

 

 

 

parameters

You will set the persistent bindings after the storage system is installed and

HBA documentation

 

 

the switches are zoned.

(see URL on

 

 

For an Emulex HBA driver, be sure to set the following parameter:

page 5-4)

 

 

 

 

 

no-device-delay=0

 

 

 

CAUTION Using improper settings can cause erratic failover behavior,

 

 

 

such as greatly increased I/O delays.

 

 

 

 

 

5

Server

Install PowerPath.

PowerPath release

 

Install PowerPath

If you have a PowerPath license key, register it.

notes and PowerPath

 

for UNIX installation

 

 

 

 

and administrator’s

 

 

 

 

guide

 

 

Reboot the server to complete the installation of PowerPath.

 

 

 

Note The format command will display n+1 device entries for each LUN,

 

 

 

where n is the number of paths to the LUN. One of these entries is a

 

 

 

PowerPath device and the other n entries are native devices.

 

 

 

Install any PowerPath patches from the Software downloads page on the

 

 

 

EMC Powerlink website:

 

 

 

http://powerlink.emc.com

 

 

 

 

 

6

Storage System

Install the storage system in the cabinet, if not already installed.

Rails and cabinet

 

Install

 

 

documentation

 

 

 

 

 

 

 

 

 

5-26

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 222
Image 222
EMC 69001166 manual Remove ATF or