EMC 69001166 manual Zone additional, Driver configuration file

Models: 69001166

1 330
Download 330 pages 55.9 Kb
Page 224
Image 224

Solaris Installation Checklists

Task

 

With Access Logix

Reference Document

 

 

 

 

11

Server

Cable any additional HBA ports to the switch connected to the storage

Storage-system setup

 

Cable additional

system or to SP ports.

guide.

 

 

 

 

HBAs to switches

Checkpoint - For a SAN, verify the HBA connections to the switch by

 

 

or storage system

 

 

 

checking the LED(s) for the switch port connected to each additional HBA

 

 

 

port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the HBA port is

 

 

 

logged in to the switch port.

 

 

 

For a 2-Gigabit switch - One of the following:

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off,

 

 

 

which indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

 

 

12

Switches

For a SAN

Switch management

 

Zone additional

Zone the switches to provide a path from each additional HBA port (host

documentation

 

 

 

HBAs

initiator) to the SPs.

 

 

 

If SAN Copy, MirrorView, or MIrrorView/A is installed, create any required

 

 

 

zones.

 

 

 

Checkpoint - Use switch management software to verify the switch

 

 

 

connections to the storage system.

 

 

 

 

 

13

Server

Add persistent bindings for the new SPs and any new HBAs to the HBA

Solaris utilities kit

 

Make target SPs

driver configuration file.

administrator’s guide

 

 

 

 

available

Note Removing ATF does not remove or change the persistent bindings.

 

 

 

Edit the /kernel/drv/sd.conf file to add LUNs and their targets.

Solaris driver.conf

 

 

 

man page

 

 

Reboot the server using the reboot - - -rcommand so the HBA can see

Solaris documentation

 

 

the targets (SPs).

 

 

 

Checkpoint - Verify that each HBA sees only the targets (SPs) to which it

 

 

 

is zoned.

 

 

 

Checkpoint - Use the inquiry option of the format command to verify that

 

 

 

each path to the storage system has one arraycommpath device with an ID

 

 

 

of drive type unknown.

 

 

 

The output of this command should be Vendor DGC, Product LUNZ.

 

 

 

 

 

5-28

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 224
Image 224
EMC 69001166 manual Zone additional, Driver configuration file