Tru64 UNIX Installation Checklist

Checklist - New Tru64 UNIX Server and New Storage System Without Boot Disk

This checklist is for a new storage system that will not contain a Tru64 UNIX boot disk. If you want the new storage system to contain a boot disk, use the procedure that starts on page 6-6.

Task

 

With Access Logix

Reference Document

 

 

 

 

1

Server

Install the Fibre Channel HBAs.

HBA documentation

 

Install HBAs, drivers,

Connect a cable from each host HBA port to a switch

 

 

and cables

port.

 

 

 

 

 

 

Create an entry in /etc/ddr.dbase to provide support for

Host connectivity guide for Tru64 UNIX

 

 

CLARiiON LUNs.

and Tru64 UNIX documentation

 

 

Install the HBA driver.

HBA documentation

 

 

Checkpoint — Verify the server connections to the

 

 

 

switch by checking the LED(s) for the switch port

 

 

 

connected to each HBA port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that

 

 

 

the HBA is logged in to the switch port.

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

• The left LED is green and the right LED is off, which

 

 

 

indicates that a 1-Gbit SP port is logged in to the

 

 

 

switch port.

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which

 

 

 

indicates that a 2-Gbit HBA port is logged in to the

 

 

 

switch port.

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the

 

 

 

right LED is off, which indicates that a 2-Gbit HBA

 

 

 

port is logged in to the switch port.

 

 

 

 

 

2

Switches

Zone the switches to provide a path from each HBA

Switch management documentation

 

Zone

(host initiator) to an SP.

 

 

 

 

 

3

Storage System

Set the Base UDID (UUID on screen) for the storage

Host connectivity guide for Tru64 UNIX

 

Set Base UDID

system.

and Tru64 UNIX documentation

 

 

If necessary, you can determine the available UDID

 

 

 

ranges for the server or cluster with the following

 

 

 

command:

 

 

 

wwidmgr -show wwid

 

 

 

 

 

6-4

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 252
Image 252