Windows Installation Checklists

Task

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

10 Server

For any storage system except a

For any storage system except a

Storage-system setup

Cable additional

CX500i

CX500i

guide

 

 

 

HBAs tor NICs to

Cable any additional HBA ports to the

Cable an additional HBA ports to

 

Fibre Channel

Fibre Channel switch connected to the

the Fibre Channel switch

 

switches,

storage system or to the

connected to the storage system

 

network, or

storage-system Fibre Channel data

or to the storage-system Fibre

 

storage-system

ports.

Channel data ports.

 

data ports

 

 

 

 

Checkpoint - For a SAN, verify

Checkpoint - For a SAN, verify

 

 

the HBA connections to the

the storage-system connections

 

 

switch by checking the LED(s) for

to the switch by checking the

 

 

the switch port connected to each

LED(s) for the switch port

 

 

HBA port.

connected to each HBA port.

 

 

For a 1-Gbit switch - LED is

For a 1-Gbit switch - LED is

 

 

green, which indicates that the

green, which indicates that the

 

 

HBA port is logged in to the

HBA port is logged in to the

 

 

switch port.

switch port.

 

 

For a 2-Gbit switch - One of the

For a 2-Gbit switch - One of the

 

 

following:

following:

 

 

• The left LED is green and the

• The left LED is green and the

 

 

right LED is off, which

right LED is off, which

 

 

indicates that a 1-Gbit SP port

indicates that a 1-Gbit SP port

 

 

is logged in to the switch port.

is logged in to the switch port.

 

 

• For a DS-xxB2 switch, both

• For a DS-xxB2 switch, both

 

 

LEDs are green, which

LEDs are green, which

 

 

indicates that a 2-Gbit HBA

indicates that a 2-Gbit HBA

 

 

port is logged in to the switch

port is logged in to the switch

 

 

port.

port.

 

 

• For a DS-xxM2 switch, the left

• For a DS-xxM2 switch, the left

 

 

LED is blue and the right LED

LED is blue and the right LED

 

 

is off, which indicates that a

is off, which indicates that a

 

 

2-Gbit HBA port is logged in to

2-Gbit HBA port is logged in to

 

 

the switch port.

the switch port.

 

 

For a CX500i storage system

N/A

Storage-system setup

 

Cable any additional HBA or

 

guide

 

 

 

 

NICs ports to the network

 

 

 

connected to the storage-system

 

 

 

iSCSI data ports or directly to the

 

 

 

storage-system iSCSI data ports.

 

 

 

 

 

 

7-52

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 310
Image 310
EMC 69001166 manual CX500i, Fibre Channel switch, Ports Channel data ports, NICs ports to the network