Linux Installation Checklist

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Reference Document

 

 

 

 

 

 

 

 

 

8

Storage System

Connect the storage system to the switch or HBA ports.

Storage-system setup

 

 

 

Cable to switch

 

 

guide.

 

 

 

 

 

 

 

 

 

or server and

Checkpoint - For a SAN, verify the storage-system connections to the

 

 

 

 

LAN

 

 

 

 

switch by checking the LED(s) for the switch port connected to each SP

 

 

 

 

 

 

 

 

 

 

port.

 

 

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the SP is logged

 

 

 

 

 

in to the switch port.

 

 

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off,

 

 

 

 

 

which indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

 

 

Cable each SP to the LAN connected to the hosts from which you will

Storage-system setup

 

 

 

 

manage the storage system.

guide.

 

 

 

 

 

 

 

 

 

9

Storage System

Use Navisphere Manager to define a global administrator and domain (if

Navisphere security

 

 

 

Set up security

not already defined) and any additional users.

administrator’s guide

 

 

 

 

 

and Navisphere

 

 

 

 

 

 

 

 

 

 

 

 

Manager online help

 

 

 

 

 

 

 

 

 

10

Storage System

Use the following Navisphere CLI commands to set the following default

Navisphere CLI

 

 

 

Set Properties for

storage-system properties:

reference

 

 

 

 

 

 

 

 

 

PowerPath

navicli -h hostname systemtype -config 3

 

 

 

 

 

navicli -h hostname failovermode 1

 

 

 

 

 

navicli -h hostname arraycommpath 1

 

 

 

 

 

where hostname is the IP address or network name of an SP in the

 

 

 

 

 

storage system.

 

 

 

 

 

 

 

 

 

 

11

Switches

For a SAN

Switch management

 

 

 

Zone

Zone the switches to provide a path from each HBA port (host initiator) to

documentation

 

 

 

 

 

 

 

 

the appropriate SPs.

 

 

 

 

 

If SAN Copy, MirrorView, and/or MirrorView/A is installed, create any

 

 

 

 

 

required zones.

 

 

 

 

 

Checkpoint - Use switch management software to verify the switch

 

 

 

 

 

connections to the storage system.

 

 

 

 

 

 

 

 

 

PowerPath Checklist — New Linux Server and New Storage System

3-9

Page 117
Image 117
EMC 69001166 manual Storage-system properties Reference, Storage system Switches For a SAN, Documentation Appropriate SPs