EMC 69001166 manual Zone, Available

Models: 69001166

1 330
Download 330 pages 55.9 Kb
Page 19
Image 19

 

 

 

 

 

AIX Installation Checklists

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Task

 

With Access Logix

Reference Document

 

 

 

 

 

 

 

 

 

13

Switches

For a SAN

Switch management

 

 

 

Zone

Zone the switches to provide a path from each HBA port (host initiator) to

documentation

 

 

 

 

 

 

 

 

the appropriate SPs.

 

 

 

 

 

If MirrorView is installed, create any required zones for it.

 

 

 

 

 

Checkpoint - Use switch management software to verify the switch

 

 

 

 

 

connections to the storage system.

 

 

 

 

 

 

 

 

 

 

14

Server

Execute the following AIX command:

AIX documentation

 

 

 

Make target SPs

emc_cfgmgr.sh

 

 

 

 

available

Checkpoint - Verify that AIX sees LUNZ devices with the following AIX

 

 

 

 

 

 

 

 

 

 

command:

 

 

 

 

 

lscfg grep LUNZ

 

 

 

 

 

If AIX does not see LUNZ devices

 

 

 

 

 

• Verify that arraycommpath is set to 1 as described in step 12.

 

 

 

 

 

• Execute the following AIX command:

 

 

 

 

 

emc_cfgmgr.sh

 

 

 

 

 

Restart the Navisphere Host Agent or run the Navisphere Server Utility

CX-Series Server

 

 

 

 

with the following AIX commands:

Software for AIX

 

 

 

 

Host Agent/

Installation Guide

 

 

 

 

 

 

 

 

 

etc/rc.agent stop

 

 

 

 

 

/etc/rc.agent start

 

 

 

 

 

Server Utility

 

 

 

 

 

/usr/lpp/HOSTUTIL/naviserverutil

 

 

 

 

 

Checkpoint - Use Navisphere Manager’s Connectivity Status dialog box

Navisphere Manager

 

 

 

 

to verify that each HBA is registered with the storage system.

administrator’s guide

 

 

 

 

 

 

and online help

 

 

 

 

List the LUNZ devices with the following AIX command:

AIX documentation

 

 

 

 

lscfg grep LUNZ

 

 

 

 

 

Remove each LUNZ device with the following AIX command:

 

 

 

 

 

rmdev -dl hdiskn

 

 

 

 

 

where n is the hdisk number for the LUNZ device.

 

 

 

 

 

Execute the following AIX command:

 

 

 

 

 

emc_cfgmg.sh

 

 

 

 

 

 

 

 

 

PowerPath Checklist — New AIX Server and New Storage System

1-9

Page 19
Image 19
EMC 69001166 manual Zone, Available