HP-UX Installation Checklist

Task

 

With Access Logix

Reference Document

 

 

 

 

9

Storage System

Connect the storage system to the switch or HBA ports.

Storage-system setup

 

Cable to switch or

 

guide

 

 

 

 

server and LAN

Checkpoint - For a SAN, verify the storage-system connections to the

 

 

 

switch by checking the LED(s) for the switch port connected to each SP

 

 

 

port.

 

 

 

For a 1-Gbit switch - LED is green, which indicates that the SP is logged in

 

 

 

to the switch port.

 

 

 

For a 2-Gbit switch - One of the following:

 

 

 

• The left LED is green and the right LED is off, which indicates that a

 

 

 

1-Gbit SP port is logged in to the switch port.

 

 

 

• For a DS-xxB2 switch, both LEDs are green, which indicates that a

 

 

 

2-Gbit HBA port is logged in to the switch port.

 

 

 

• For a DS-xxM2 switch, the left LED is blue and the right LED is off, which

 

 

 

indicates that a 2-Gbit HBA port is logged in to the switch port.

 

 

 

Cable each SP to the LAN connected to the hosts from which you will

 

 

 

manage the storage system.

 

 

 

 

 

10

Storage System

Use Navisphere Manager to define a global administrator and domain (if

Navisphere security

 

Set up security

not already defined) and any additional users.

administrator’s guide

 

 

and Navisphere

 

 

 

 

 

 

Manager online help

 

 

 

 

11

Storage System

From a laptop connected to the storage system, as described in the

Storage-system

 

Set properties for

storage-system initialization or setup guide, use the following Navisphere

initialization guide and

 

CLI commands to set the default storage-system properties:

Navisphere CLI

 

PowerPath

 

 

reference

 

 

navicli -h hostname failovermode 1

 

 

 

 

 

navicli -h hostname arraycommpath 1

 

 

 

where hostname is the IP address or network name of an SP in the storage

 

 

 

system.

 

 

 

 

 

2-28