EMC 69001166 manual For PowerPath

Models: 69001166

1 330
Download 330 pages 55.9 Kb
Page 118
Image 118

Linux Installation Checklist

Task

 

With Access Logix

Reference Document

 

 

 

 

12

Server

Add persistent bindings to the HBA driver configuration file.

HBA documentation

 

Make target SPs

Note: You need the WWPN of each SP port for the bindings.

(see URL on page 3-4)

 

 

 

available

 

 

 

 

Reboot the server.

Linux documentation

 

 

Checkpoint - Use Navisphere Manager’s Connectivity Status dialog box

Navisphere Manager

 

 

to verify that each HBA is registered with the storage system.

administrator’s guide

 

 

 

and online help

 

 

Checkpoint - Make sure the /proc/scsi/scsi directory has entries for

Linux documentation

 

 

LUNZs.

 

 

 

Note: LUNZs are required to register the server HBAs with the storage

 

 

 

system because LUNs have not be configured yet.

 

 

 

Checkpoint - Make sure the file /proc/scsi file in the directory for HBAs,

 

 

 

has entries for the expected targets (HBAs).

 

 

 

 

 

13

Server

Make sure you have 128 sd and sg devices in the /dev directory.

PowerPath for Linux

 

Prepare Server

 

installation guide

 

 

 

 

for PowerPath

Ensure that the PowerPath driver’s major numbers (232-239) are not

 

 

 

 

 

 

already in use.

 

 

 

 

 

14

Storage System

Use Navisphere Manager to set general storage-system properties.

Navisphere Manager

 

Configure

Use Navisphere Manager to create RAID Groups, bind LUNs, create

administrator’s guide

 

and online help

 

 

 

 

Storage Groups, and assign LUNs to Storage Groups.

 

 

 

Use Navisphere Manager to connect the server to a Storage Group.

 

 

 

Reload the driver (if the driver is loaded as a module) or reboot the server

HBA documentation

 

 

(if the driver is static to the kernel) so that Linux recognizes the LUNs.

 

 

 

Now the LUNs in the Storage Group look like any other disks in the server.

 

 

 

Checkpoint - Make sure all LUNs have entries in the /proc/scsi/scsi file

Linux documentation

 

 

and in the directory for the HBAs in the /proc/scsi directory.

 

 

 

If all LUN entries are missing from the file, verify the zoning. If only some

Navisphere Manager

 

 

LUNs are missing, use Navisphere Manager to check that the LUNs are

online help

 

 

assigned to the server’s Storage Group.

 

 

 

 

 

3-10

EMC Installation Roadmap for CX-Series and FC-Series Storage Systems

Page 118
Image 118